Suppr超能文献

一种新型瞄准加压装置及技术在马舟骨骨折修复中的应用:一项尸体研究。

Use of a new aiming compression device and technique for the repair of navicular bone fractures in horses: A cadaveric study.

作者信息

Pudert Tanja, Fries Giuletta Felicia, Lotz Hannah, Röcken Michael, Cruz Antonio M

机构信息

Equine Clinic, Department of Surgery and Orthopedics, Faculty of Veterinary Medicine, Justus-Liebig-University Giessen, Giessen, Germany.

出版信息

Vet Surg. 2025 Jan;54(1):98-106. doi: 10.1111/vsu.14152. Epub 2024 Aug 16.

Abstract

OBJECTIVE

To assess the use of a newly developed aiming compression device (ACD) for screw insertion in non-fractured navicular bones (NB) in cadavers.

STUDY DESIGN

Cadaveric study.

SAMPLE POPULATION

A total of 10 cadaveric front limbs of adult horses.

METHODS

Placement of a 3.5 mm cortical screw in non-fractured NB under radiographic guidance was performed in 10 cadaver limbs in a standing position. An ACD was used to stabilize the NB and to guide the drilling process. Preparation and surgical time as well as the number of radiographic images were noted. A postoperative scoring system was used to assess screw placement by cone beam computed tomography (CBCT) and gross examination by two evaluators.

RESULTS

The total procedure time was 25-62 min (median 33.5). During the procedure, 11-21 radiographs (median 18.5) were taken. The postoperative gross examination revealed an excellent screw placement in nine NB and poor in one. This could not be reliably assessed with post-procedure CBCT.

CONCLUSION

The described technique achieves an excellent screw placement in 9/10 bones without disrupting the articular or flexural surface of the NB and with no protrusion of the screw head or tip, in a median procedure time of under 35 min.

CLINICAL SIGNIFICANCE

Adequate screw placement is paramount for NB fracture repair. The described approach under radiographic guidance allows adequate screw placement using the ACD to stabilize the NB by lateral to medial compression. This technique facilitates adequate screw placement within the NB without the use of advanced imaging techniques.

摘要

目的

评估一种新开发的瞄准加压装置(ACD)在尸体非骨折舟状骨(NB)中插入螺钉的应用情况。

研究设计

尸体研究。

样本总体

总共10只成年马的尸体前肢。

方法

在10具尸体站立位的肢体上,在X线透视引导下,于非骨折的NB中置入一枚3.5毫米皮质骨螺钉。使用ACD稳定NB并引导钻孔过程。记录准备时间、手术时间以及X线透视图像数量。采用术后评分系统,通过锥形束计算机断层扫描(CBCT)和两名评估者的大体检查来评估螺钉置入情况。

结果

总手术时间为25 - 62分钟(中位数33.5分钟)。手术过程中,拍摄了11 - 21张X线片(中位数18.5张)。术后大体检查显示,9个NB的螺钉置入情况良好,1个较差。术后CBCT无法可靠评估。

结论

所描述的技术在9/10的骨骼中实现了良好的螺钉置入,未破坏NB的关节面或弯曲面,螺钉头部或尖端无突出,中位手术时间不到35分钟。

临床意义

对于NB骨折修复,合适的螺钉置入至关重要。所描述的在X线透视引导下的方法,使用ACD通过从外侧到内侧的加压来稳定NB,从而实现合适的螺钉置入。该技术无需使用先进的成像技术就能在NB内实现合适的螺钉置入。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c95c/11734874/f142fc3a5e05/VSU-54-98-g004.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验