Suppr超能文献

青少年患者10毫米骨-髌腱-骨自体移植物的关节内腱性移植物直径:100例患者的MRI分析

The Intra-articular Tendinous Graft Diameter of 10-mm Bone-Patellar Tendon-Bone Autografts in Adolescent Patients: An MRI Analysis of 100 Patients.

作者信息

Beber Samuel A, Jones Ruth H, Cirrincione Peter, Gross Preston W, Green Daniel W, Greditzer Harry G, Heyworth Benton E, Fabricant Peter D

机构信息

Hospital for Special Surgery, New York, New York, USA.

New York Medical College, Valhalla, New York, USA.

出版信息

Orthop J Sports Med. 2024 Aug 19;12(8):23259671241264503. doi: 10.1177/23259671241264503. eCollection 2024 Aug.

Abstract

BACKGROUND

Bone-patellar tendon-bone (BPTB) autograft size may be one modifiable predictor of anterior cruciate ligament (ACL) reconstruction postoperative success, as smaller graft diameter has been associated with higher rates of rupture requiring revision. However, measuring the true intra-articular tendinous graft diameter of the soft tissue portion of a BPTB graft with standard intraoperative methods is difficult while keeping the graft intact.

PURPOSE/HYPOTHESIS: The purpose of the study was to use 3-dimensional magnetic resonance imaging (MRI) measurements to determine the cross-sectional area of the soft tissue, tendinous portion of a standard BPTB autograft with 10-mm diameter bone plugs, and, by calculation, the collagen graft size (ie, graft diameter), as would typically be reported in ACL reconstruction studies that consider soft tissue graft size. It was hypothesized that the calculated collagen graft diameter of 10-mm BPTB autografts would be significantly smaller than 10 mm.

STUDY DESIGN

Cross-sectional study; Level of evidence, 3.

METHODS

A total of 100 patients (10 girls and 10 boys at each age from 13 to 17 years) who underwent a knee MRI at a single academic orthopaedic center without documented extensor mechanism pathology were identified. The central 10-mm width of the patellar tendon that would be harvested for BPTB autograft was measured. The region of interest area tool was then used to measure the cross-sectional area of a 10-mm BPTB graft with subsequent soft tissue autograft diameter calculation.

RESULTS

The mean calculated tendinous graft diameter of a 10 mm-wide BPTB graft was 6.3 ± 0.5 mm and was significantly smaller than a 10-mm reference (≤ .001). There was no significant association between age and cross-sectional area or graft diameter.

CONCLUSION

Modern 3-dimensional imaging-based measurement techniques demonstrated that the true intra-articular tendinous soft tissue portion of 10-mm BPTB autografts shows substantial variation and is significantly smaller in diameter than the tunnels typically reamed to accommodate the bone plug portions of these grafts. Moreover, as graft size is a predictor of rupture rate, preoperative MRI-based evaluation may be an important tool when considering BPTB autograft for ACL reconstruction. Future comparative clinical research utilizing graft size as a study variable should consider quantifying and utilizing the diameter of the soft tissue component of BPTB autografts.

摘要

背景

髌腱-骨(BPTB)自体移植物的大小可能是前交叉韧带(ACL)重建术后成功的一个可改变的预测因素,因为较小的移植物直径与需要翻修的较高破裂率相关。然而,使用标准术中方法测量BPTB移植物软组织部分的真正关节内腱性移植物直径,同时保持移植物完整是困难的。

目的/假设:本研究的目的是使用三维磁共振成像(MRI)测量来确定带有10毫米直径骨栓的标准BPTB自体移植物的软组织腱性部分的横截面积,并通过计算得出胶原移植物大小(即移植物直径),这是在考虑软组织移植物大小的ACL重建研究中通常会报告的数值。假设10毫米BPTB自体移植物计算出的胶原移植物直径将显著小于10毫米。

研究设计

横断面研究;证据等级,3级。

方法

在一个单一的学术骨科中心,共识别出100例患者(13至17岁,每个年龄组10名女孩和10名男孩),他们接受了膝关节MRI检查,且无伸膝机制病变记录。测量了将用于BPTB自体移植物的髌腱中央10毫米宽度。然后使用感兴趣区域工具测量10毫米BPTB移植物的横截面积,并随后计算软组织自体移植物直径。

结果

10毫米宽的BPTB移植物计算出的平均腱性移植物直径为6.3±0.5毫米,显著小于10毫米的参考值(≤.001)。年龄与横截面积或移植物直径之间无显著关联。

结论

基于现代三维成像的测量技术表明,10毫米BPTB自体移植物真正的关节内腱性软组织部分存在显著差异,其直径明显小于通常为容纳这些移植物的骨栓部分而扩髓的隧道直径。此外,由于移植物大小是破裂率的一个预测因素,在考虑使用BPTB自体移植物进行ACL重建时,基于术前MRI的评估可能是一个重要工具。未来将移植物大小作为研究变量的比较临床研究应考虑量化并使用BPTB自体移植物软组织成分的直径。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/dea9/11334251/0503774f7ee8/10.1177_23259671241264503-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验