Abstract

: Target tetra detachable coils (TTDCs) aid in achieving effective framing during the coil embolization of small intracranial aneurysms by maintaining a tetrahedral conformation within the aneurysm sac. We aimed to report the initial experience of patients treated for intracranial aneurysms using TTDCs, with a specific focus on efficacy and safety. : We retrospectively reviewed the medical records of 41 patients who underwent the coil embolization of intracranial aneurysms sized ≤10 mm with TTDCs between April and May 2023. Post-procedural angiographic and clinical results were reviewed. : Of the 46 aneurysms (45 unruptured and 1 ruptured), 33 (71.7%) were treated with the stent-assisted technique and 13 (28.3%) using the simple coil embolization technique. Post-procedural angiography showed complete occlusion in 41 aneurysms (89.1%), neck remnants in 1 (2.2%), and residual aneurysms in 4 (8.7%). The mean packing density was 34.7% (19.3-46.8%), with TTDC coil length comprising a mean of 88.5% of the total coil length. No major device- or procedure-related complications were observed. During the follow-up, 40 aneurysms (93.0%) demonstrated complete occlusion, while neck remnants were observed in 1 (2.3%), and residual aneurysms in 2 (4.7%). No cases of recanalization were observed. : The TTDC is a safe and effective device for the endovascular treatment of intracranial aneurysms. Follow-up studies are required to establish long-term results.

摘要

目标四面体可分离线圈(TTDCs)通过在动脉瘤腔内维持四面体构象,有助于在小型颅内动脉瘤的线圈栓塞过程中实现有效的成篮。我们旨在报告使用TTDCs治疗颅内动脉瘤患者的初步经验,特别关注疗效和安全性。我们回顾性分析了2023年4月至5月期间41例行TTDCs治疗的颅内动脉瘤直径≤10mm患者的病历。对术后血管造影和临床结果进行了评估。在46个动脉瘤(45个未破裂和1个破裂)中,33个(71.7%)采用支架辅助技术治疗,13个(28.3%)采用单纯线圈栓塞技术治疗。术后血管造影显示41个动脉瘤(89.1%)完全闭塞,1个(2.2%)有颈部残留,4个(8.7%)有残余动脉瘤。平均填充密度为34.7%(19.3 - 46.8%),TTDC线圈长度平均占总线圈长度的88.5%。未观察到与器械或操作相关的重大并发症。随访期间,40个动脉瘤(93.0%)显示完全闭塞,1个(2.3%)有颈部残留,2个(4.7%)有残余动脉瘤。未观察到再通病例。TTDC是一种用于颅内动脉瘤血管内治疗的安全有效的器械。需要进行随访研究以确定长期结果。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6c21/11355286/db8df06daaec/jcm-13-04940-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验