Suppr超能文献

一种用于男性大鼠经尿道无创伤性导尿的新方法。

A novel technique for atraumatic transurethral catheterisation of male rats.

机构信息

Plastic, Reconstructive and Aesthetic Surgery Service, Department of General Surgery, Woodlands Health, Singapore 737628, Singapore.

Plastic, Reconstructive & Aesthetic Surgery Service, Sengkang General Hospital, Singapore 544886, Singapore.

出版信息

Biol Open. 2024 Sep 15;13(9). doi: 10.1242/bio.060476. Epub 2024 Aug 30.

Abstract

Transurethral catheterisation of male rats is technically difficult owing to anatomical peculiarities. In the male rat, the urethral striated sphincter consists of two lateral fascicles separated by an anterior and a posterior strip of connective tissue, which impedes the smooth insertion of a urinary catheter. For rat studies requiring continuous collection of urine, bladder irrigation, or measurement of bladder pressure, investigators either have to exclude the male population (be limited to the female population) or perform percutaneous (suprapubic) bladder puncture in male rats, which is more traumatic and invasive than transurethral catheterisation. This paper describes a novel, atraumatic method of transurethral catheterisation in the male rat, with the aid of a microscope and microsurgical instruments. Six Wistar rats were used for this experiment, all of which were catheterised successfully, with no evidence of bladder or urethral injury. The study shows that male rats can be safely catheterised via the urethra with the aid of a microscope and microsurgical instruments for both visual and tactile feedback. This is a relatively straightforward technique to learn and can allow for inclusion of male rats in future studies requiring urinary analysis or bladder irrigation, without the need for traumatic percutaneous (suprapubic) bladder puncture.

摘要

经尿道男性大鼠插管技术难度大,这主要是由于其解剖学特点所致。在雄性大鼠中,尿道横纹括约肌由两个外侧束组成,中间由前、后两条结缔组织带隔开,这会阻碍导尿管的顺利插入。对于需要连续收集尿液、膀胱冲洗或测量膀胱压力的大鼠研究,研究人员要么不得不排除雄性(仅限于雌性),要么对雄性大鼠进行经皮(耻骨上)膀胱穿刺,后者比经尿道插管更具创伤性和侵入性。本文介绍了一种在显微镜和显微手术器械辅助下对雄性大鼠进行经尿道插管的新方法,该方法无创伤。该实验使用了 6 只 Wistar 大鼠,所有大鼠均成功插管,且膀胱和尿道均无损伤证据。研究表明,在显微镜和显微手术器械的辅助下,雄性大鼠可以通过尿道安全地进行插管,从而获得视觉和触觉反馈。这是一种相对简单的技术,易于掌握,可以让雄性大鼠纳入未来需要尿液分析或膀胱冲洗的研究中,而无需进行创伤性的经皮(耻骨上)膀胱穿刺。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/ffda/11381925/4148233183cf/biolopen-13-060476-g1.jpg