Percutaneously inserted spinal epidural neurostimulation has been derived as a simplified safe alternative to surgically implanted, dorsal column stimulation that is used in the effective treatment and control of spasticity and intractable pain. Twenty-seven tissue specimens from fifteen patients having had percutaneous epidural neurostimulation systems implanted were studied with the aid of light microscopy. The biopsies from tissues around the cables, around the receivers, and at the actual site of epidural stimulation (at the metallic contact), were studied at time intervals varying from one week to two years postimplantation. Long-term results, which only show dense fibrous encapsulation of the cables and the receiver, substantiate clinical belief regarding the "histological safety" of this electronic modality.

摘要

经皮插入式脊髓硬膜外神经刺激术已被开发出来,作为手术植入式背柱刺激术的一种简化且安全的替代方法,后者用于有效治疗和控制痉挛及顽固性疼痛。对15名植入了经皮硬膜外神经刺激系统的患者的27个组织样本进行了光学显微镜检查。对植入后1周-2年不等时间间隔的电缆周围、接收器周围以及硬膜外刺激实际部位(金属接触处)的组织活检样本进行了研究。长期结果仅显示电缆和接收器有致密的纤维包裹,证实了关于这种电子方式“组织学安全性”的临床观点。