McMillan Sean, Clancy Dillon, Ford Elizabeth
Virtua Health System, Willingboro & Camden Campuses, Willingboro, New Jersey, U.S.A.
Orthopedic Surgery, Inspira Health Network, St. Davids, Pennsylvania, U.S.A.
Arthrosc Tech. 2024 May 9;13(8):103022. doi: 10.1016/j.eats.2024.103022. eCollection 2024 Aug.
The portal of Willingboro is a unique portal designed as a means of all arthroscopic biceps tenodesis for biceps tendinopathy. The portal allows for tenodesis to be efficiently and effectively performed in the subgroove space with low technical demand. This Technical Note provides detailed descriptions of the anatomical structures and standard shoulder arthroscopy portals relevant to the location of the portal of Willingboro. The structures discussed include the standard anterior, posterior, and lateral shoulder arthroscopy portals along with the axillary and musculocutaneous nerves, subscapularis and pectoralis major tendons, axillary artery, and major bony anatomic landmarks of the shoulder region. These descriptions may be used as a guideline or reference for safe creation of the portal of Willingboro.
威灵伯勒入路是一种独特的入路,设计用于作为治疗肱二头肌肌腱病的所有关节镜下肱二头肌肌腱固定术的一种手段。该入路允许在低技术要求的情况下,在肱二头肌沟下间隙高效且有效地进行肌腱固定术。本技术说明详细描述了与威灵伯勒入路位置相关的解剖结构和标准肩关节镜入路。所讨论的结构包括标准的肩关节镜前、后和外侧入路,以及腋神经和肌皮神经、肩胛下肌腱和胸大肌腱、腋动脉和肩部区域的主要骨性解剖标志。这些描述可作为安全创建威灵伯勒入路的指导或参考。