Orbital implants and prostheses: postoperative computed tomographic appearance.

作者信息

Gale M E, Vincent M E, Sutula F C

出版信息

AJNR Am J Neuroradiol. 1985 May-Jun;6(3):403-7.

Abstract

Computed tomographic (CT) scans of 19 patients with 10 right and nine left orbital implants were reviewed. Except for orbital soft-tissue swelling due to recent surgery or infection, CT scans obtained with both the implant and prosthesis in place showed relative symmetry of the postoperative side and the native globe. Benign air collections were often associated with either the implant or prosthesis interface or with seating of the prosthesis in the conjunctival fornices. Six patients had either cartilage, silicone, or glass beads placed surgically along the orbital floor to elevate the implants, four having had prior depressed orbital floor fractures. CT identified implant migration in five patients. The orbital prosthesis, usually constructed of solid methylmethacrylate, is fitted over the implant and simulates the appearance of the eye of the contralateral side. The operative anatomy and its relation to the CT appearance of the implant and external prosthesis are reviewed.

摘要

回顾了19例患者的计算机断层扫描(CT)图像,其中10例植入右侧眼眶植入物,9例植入左侧眼眶植入物。除了近期手术或感染导致的眼眶软组织肿胀外,植入物和假体均在位时获得的CT扫描显示术后侧与健侧眼球相对对称。良性积气常与植入物或假体界面相关,或与假体在结膜穹窿部的就位有关。6例患者手术时在眶底放置了软骨、硅胶或玻璃珠以抬高植入物,其中4例曾有眶底凹陷性骨折。CT检查发现5例患者的植入物发生移位。眼眶假体通常由实心甲基丙烯酸甲酯制成,安装在植入物上,模拟对侧眼睛的外观。本文回顾了手术解剖结构及其与植入物和外部假体CT表现的关系。

相似文献

7
Orbital floor implant migration across the ethmoidal sinuses and nasal septum.
Am J Ophthalmol. 1998 Dec;126(6):848-50. doi: 10.1016/s0002-9394(98)00239-6.
8
The diagnosis of infections associated with acrylic cranioplasties.
Neuroradiology. 1990;32(2):151-3. doi: 10.1007/BF00588566.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验