Department of Orthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Department of Orthodontics, Faculty of Dentistry, Mansoura University, Mansoura, Egypt.
Int Orthod. 2024 Dec;22(4):100915. doi: 10.1016/j.ortho.2024.100915. Epub 2024 Sep 5.
The removal of adhesive remnants after bracket debonding has been shown to cause damaging effects on the enamel surface. This study aimed to investigate the efficacy of stained adhesive remnant removal (ARR) on enamel roughness compared to translucent composite.
Thirty extracted premolar teeth were divided equally into three groups; conventional composite control group (CC), stained composite group (SC) and stained bonding solution group (SB). The buccal surface of each tooth was cleaned, dried and the surface roughness (Ra) was evaluated using a contact prophylometer (T0). After bracket debonding, a high-speed carbide bur under a water-cooling system was used for ARR in one direction and the time consumed for ARR was recorded. After ARR, the second mean Ra values were recorded (T1). The samples were then polished using polishing paste with low-speed rubber cup and the third mean Ra values were recorded (T2).
Repeated one-way ANOVA revealed a significant difference in the mean Ra values at T0, T1 and T2 within each group P<0.05. A statistically significant difference in the changes of the mean Ra values after ARR (T1-T0) and after polishing (T1-T2) was found between the CC group and both SC and SB groups. A significant difference in the time consumed for ARR was found between the three groups with CC group being the most time-consuming group.
Stained composite material followed by the stained bonding solution provided better visibility during ARR with lower mean Ra values and less time for ARR compared totranslucent composite material.
已证明,去除托槽脱落后的残留粘结剂会对釉质表面造成损害。本研究旨在比较染色残留粘结剂去除(ARR)对釉质粗糙度的效果与半透明复合树脂的效果。
将 30 颗离体前磨牙等分为三组:常规复合树脂对照组(CC)、染色复合树脂组(SC)和染色粘结剂组(SB)。每组牙齿的颊面均进行清洁、干燥,并用接触式测微仪(T0)评估表面粗糙度(Ra)。托槽脱落后,使用高速碳化钨钻在水冷系统下单向进行 ARR,并记录 ARR 所用时间。ARR 后,记录第二次平均 Ra 值(T1)。然后,使用低速橡胶杯和抛光膏对样本进行抛光,记录第三次平均 Ra 值(T2)。
重复测量方差分析显示,每组 T0、T1 和 T2 时的平均 Ra 值均存在显著差异(P<0.05)。CC 组与 SC 组和 SB 组在 ARR 后(T1-T0)和抛光后(T1-T2)平均 Ra 值变化方面存在统计学差异。ARR 所用时间在三组之间存在显著差异,CC 组用时最长。
与半透明复合树脂相比,染色复合树脂随后使用染色粘结剂在 ARR 时提供了更好的可视性,Ra 值更低,ARR 时间更短。