This study aimed to compare the marginal adaptation of a single customized gutta percha cone with calcium silicate-based sealer versus mineral trioxide aggregate (MTA) and Biodentine apical plugs in simulated immature permanent teeth.
Thirty-nine extracted human maxillary anterior teeth were selected, prepared to simulate immature permanent teeth with an apical diameter 1.1 mm, placed in moist foam and divided into three groups. Group 1: Obturation with a single customized gutta percha cone and calcium silicate sealer. Group 2: MTA apical plug. Group 3: Biodentine apical plug. After incubation, teeth were horizontally sectioned at 1 mm and 3 mm from the apex and marginal adaptation was evaluated using scanning electron microscope (SEM).
Biodentine showed the least mean gap size at both 1 and 3 mm from the apex with no statistically significant differences compared to MTA (p > 0.05). The single customized cone with calcium silicate based sealer showed the greatest mean gap size at both 1 and 3 mm from the apex with a statistically significant difference compared to the other groups (p < 0.001).
Biodentine and MTA apical plugs provide a significantly better marginal adaptation to the dentinal walls than a single customized gutta percha cone with calcium silicate based sealer in simulated immature permanent teeth.
本研究旨在比较单根定制化牙胶尖与基于硅酸钙的密封剂、矿物三氧化物聚合体(MTA)和 Biodentine 根尖塞在模拟未成熟恒牙中的边缘适应性。
选择 39 颗上颌前磨牙,模拟未成熟恒牙,根尖直径 1.1mm,置于湿泡沫中,分为三组。第 1 组:用单根定制化牙胶尖和硅酸钙密封剂进行根管填充。第 2 组:MTA 根尖塞。第 3 组:Biodentine 根尖塞。孵育后,牙齿在距根尖 1mm 和 3mm 处水平切片,用扫描电子显微镜(SEM)评估边缘适应性。
Biodentine 在距根尖 1mm 和 3mm 处的平均间隙最小,与 MTA 相比无统计学差异(p>0.05)。单根定制化牙胶尖和硅酸钙基密封剂在距根尖 1mm 和 3mm 处的平均间隙最大,与其他两组相比有统计学差异(p<0.001)。
在模拟未成熟恒牙中,Biodentine 和 MTA 根尖塞在牙本质壁的边缘适应性明显优于单根定制化牙胶尖和硅酸钙基密封剂。