Suppr超能文献

一种用于八孔钢板半骨骺阻滞术的新型微创手术技术:描述与评估

A Novel Minimally Invasive Surgical Technique for Eight-Plate Hemiepiphysiodesis: Description and Evaluation.

作者信息

Heisinger Stephan, Sommeregger Johannes, Trost Carmen, Willegger Madeleine, Schreiner Markus, Windhager Reinhard, Kolb Alexander

机构信息

Department of Orthopedics and Trauma Surgery, Medical University of Vienna, 1090 Vienna, Austria.

Teaching Center, Medical University of Vienna, 1090 Vienna, Austria.

出版信息

J Clin Med. 2024 Sep 2;13(17):5197. doi: 10.3390/jcm13175197.

Abstract

Temporary hemiepiphysiodesis with tension band plates or eight-plates is a common surgical procedure to treat malalignment of the lower limb axis in skeletally immature patients. The objective of this study was to compare a new minimally invasive surgical procedure with the conventional procedure and evaluate its safety and effectiveness in order to reduce the risk of hypertrophic scarring, which may cause functional impairment as well as cosmetic issues. Sixty-five growth plates of either the femur or the tibia were evaluated in 33 patients treated for genu valgum or varum between 2010 and 2017. Each growth plate was considered an individual case. The modified procedure was used in 17 cases and the conventional procedure in 48 cases. The modified surgical procedure is characterized by an 8 mm incision and preparation of the epi-periosteal layer, in which the eight-plate is positioned via a guide-wire. Positioning and implantation are controlled via fluoroscopy. Skin incision length, duration of surgery, revision rate, achievement of a defined correction goal, and correction rate were analyzed. Using the minimally invasive procedure, the mean skin incision length (23.94 ± 10.18 mm vs. 8.75 ± 2.14 mm, < 0.001) could be significantly reduced. No significant difference was found in regard to the duration of surgery, revision rate, achievement of the correction goal or correction rate. The minimally invasive procedure results in a reduction in incision length without significant impact on the duration of surgery, revision rate, achievement of correction goal or correction rate. Consequently, the modified procedure can be regarded as equally as effective and safe as the conventional procedure.

摘要

采用张力带钢板或八孔钢板进行临时半骨骺阻滞术是治疗骨骼未成熟患者下肢力线排列不齐的常见外科手术。本研究的目的是将一种新的微创手术与传统手术进行比较,并评估其安全性和有效性,以降低增生性瘢痕的风险,增生性瘢痕可能导致功能障碍以及美观问题。在2010年至2017年间,对33例接受膝外翻或膝内翻治疗的患者的65块股骨或胫骨生长板进行了评估。每块生长板被视为一个单独的病例。17例采用改良手术,48例采用传统手术。改良手术的特点是切口8毫米,并制备骨膜上层,通过导丝将八孔钢板置于该层。通过荧光透视控制定位和植入。分析了皮肤切口长度、手术时间、翻修率、是否达到既定矫正目标以及矫正率。采用微创手术,平均皮肤切口长度可显著缩短(23.94±10.18毫米对8.75±2.14毫米,<0.001)。在手术时间、翻修率、是否达到矫正目标或矫正率方面未发现显著差异。微创手术可缩短切口长度,且对手术时间、翻修率、是否达到矫正目标或矫正率无显著影响。因此,改良手术可被视为与传统手术同样有效和安全。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/a93a/11396604/31a85682e565/jcm-13-05197-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验