Suppr超能文献

在标准和虚拟现实观看条件下,瞳孔视野计检测偏盲的诊断性能。

Diagnostic performance of pupil perimetry in detecting hemianopia under standard and virtual reality viewing conditions.

作者信息

Portengen Brendan, Imhof Saskia, Naber Marnix, Porro Giorgio

机构信息

Ophthalmology Department, University Medical Center Utrecht, Room E 03.136, PO Box 85500, 3508 GA, Utrecht, The Netherlands.

Experimental Psychology, Helmholtz Institute, Utrecht University, Utrecht, The Netherlands.

出版信息

Graefes Arch Clin Exp Ophthalmol. 2025 Feb;263(2):537-546. doi: 10.1007/s00417-024-06641-4. Epub 2024 Sep 18.

Abstract

PURPOSE

To determine the diagnostic performance and reliability of two pupil perimetry (PP) methods in homonymous hemianopia.

METHODS

This cross-sectional monocenter cohort study performed gaze-contingent flicker PP (gcFPP) and a virtual reality version of gcFPP (VRgcFPP) twice on separate occasions in all patients suffering from homonymous hemianopia due to neurological impairment. The main outcomes were (1) test accuracy and (2) test-retest reliability: (1) was measured through area under the receiver operating characteristics curve (AUC) calculation of (VR)gcFPP results with comparators being SAP and healthy controls, respectively; (2) was evaluated by comparing tests 1 and 2 of both methods within patients.

RESULTS

Both gcFPP and VRgcFPP were performed in 15 patients (12 males, M = 57, SD = 15) and 17 controls (6 males, M = 53, SD = 12). Mean test accuracy was good in separating damaged from intact visual field regions (gcFPP: M = 0.83, SD = 0.09; VRgcFPP: M = 0.69, SD = 0.13) and in separating patients from controls (gcFPP: M = 0.92, SD = 0.13; VRgcFPP: M = 0.96, SD = 0.15). A high test-retest reliability was found for the proportion intact versus damaged visual field (gcFPP: r = 0.95, P < .001, VRgcFPP: r = 1.00, P < .001).

CONCLUSIONS

Overall, these results can be summarized as follows: (1) the comparison of pupil response amplitudes between intact versus damaged regions per patient indicate that gcFPP allows for cleaner imaging of intact versus damaged visual field regions than VRgcFPP, (2) the comparisons of average differences in intact versus damaged amplitudes between patients and controls demonstrate high diagnostic performance of both gcFPP and VRgcFPP, and (3) the test-retest reliabilities confirm that both gcFPP and VRgcFPP reliably and consistently measure defects in homonymous hemianopia. KEY  MESSAGES: What is known Standard automated perimetry is the current gold standard for visual field examination, but not always suited for the evaluation of the VF in neurologically impaired patients. Pupil perimetry consists of the measurement of pupillary responses to light stimuli as a measure of visual sensitivity. What is new This study reports the highest diagnostic accuracy of pupil perimetry so far in patients with homonymous hemianopia. Gaze-contingent flicker pupil perimetry reliably and consistently measures defects in homonymous hemianopia under standard and virtual reality viewing conditions.

摘要

目的

确定两种瞳孔视野计(PP)方法在同侧偏盲中的诊断性能和可靠性。

方法

这项横断面单中心队列研究,对所有因神经损伤导致同侧偏盲的患者,在不同时间分别进行两次注视性闪烁PP(gcFPP)和虚拟现实版的gcFPP(VRgcFPP)。主要结果包括:(1)测试准确性;(2)重测可靠性:(1)通过计算(VR)gcFPP结果的受试者工作特征曲线下面积(AUC)来衡量,比较对象分别为标准自动视野计(SAP)和健康对照;(2)通过比较患者体内两种方法的第一次和第二次测试来评估。

结果

15例患者(12例男性,M = 57,SD = 15)和17例对照(6例男性,M = 53,SD = 12)均接受了gcFPP和VRgcFPP检查。在区分受损与完整视野区域方面,平均测试准确性良好(gcFPP:M = 0.83,SD = 0.09;VRgcFPP:M = 0.69,SD = 0.13),在区分患者与对照方面也良好(gcFPP:M = 0.92,SD = 0.13;VRgcFPP:M = 0.96,SD = 0.15)。对于完整视野与受损视野的比例,发现重测可靠性较高(gcFPP:r = 0.95,P <.001,VRgcFPP:r = 1.00,P <.001)。

结论

总体而言,这些结果可总结如下:(1)每位患者完整区域与受损区域之间瞳孔反应幅度的比较表明,与VRgcFPP相比,gcFPP能更清晰地成像完整与受损视野区域;(2)患者与对照之间完整幅度与受损幅度平均差异的比较表明,gcFPP和VRgcFPP均具有较高的诊断性能;(3)重测可靠性证实,gcFPP和VRgcFPP均能可靠且一致地测量同侧偏盲中的缺陷。关键信息:已知内容 标准自动视野计是目前视野检查的金标准,但并不总是适用于评估神经受损患者的视野。瞳孔视野计包括测量瞳孔对光刺激的反应,作为视觉敏感度的一种测量方法。新内容 本研究报告了迄今为止瞳孔视野计在同侧偏盲患者中的最高诊断准确性。注视性闪烁瞳孔视野计在标准和虚拟现实观察条件下,能可靠且一致地测量同侧偏盲中的缺陷。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5d3d/11868179/dcb2bd0e8403/417_2024_6641_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验