从事血管和介入放射学程序的医务人员接触电离辐射。

Exposure to ionizing radiation of medical staff performing vascular and interventional radiology procedures.

机构信息

Medical University of Lodz, Łódź, Poland (Faculty of Medicine, Department of Medical Imaging Technology).

Copernicus Memorial Hospital in Lodz Comprehensive Cancer Center and Traumatology, Łódź, Poland (Department of Medical Physics).

出版信息

Int J Occup Med Environ Health. 2024 Nov 6;37(4):403-410. doi: 10.13075/ijomeh.1896.02462. Epub 2024 Sep 11.

Abstract

OBJECTIVES

Vascular and interventional radiology procedures are characterized by high exposure of personnel to ionizing radiation. This study assessed the exposure of medical personnel to ionizing radiation during vascular radiology and mechanical thrombectomy procedures.

MATERIAL AND METHODS

During vascular radiology procedures, the exposure of 4 groups of workers participating in the procedures was analyzed, i.e., the main operating physician, an assistant physician, a sterile nurse, and a nurse. Measurements of exposure to ionizing radiation were performed using thermoluminescent dosimetry.

RESULTS

The registered effective dose during 1 treatment in individual groups is, respectively: mean (M) ± standard deviation (SD) 75±15 μSv, 24±5 μSv, 13±3 μSv, and 8±2 μSv. During mechanical thrombectomy, the operating physician receives an effective dose of M±SD 9±2 μSv. The equivalent doses for the lenses for the operating physician and the doctor assisting during vascular radiology procedures are M±SD 1419±285 μSv and 987±198 μSv, respectively, and for the hands, including the left and right hands, M±SD 4605±930 μSv, 1420±284 μSv, 1898±380 μSv, 1371±274 μSv.

CONCLUSIONS

If the principles of optimizing radiological protection are not applied during vascular radiology procedures, the permissible dose limits and operational limits equivalent to doses to lenses and hands may be exceeded. Exposure during vascular radiology procedures is comparable to exposure during nuclear medicine procedures in terms of the use of glucose labeled with radioactive fluorine. Int J Occup Med Environ Health. 2024;37(4):403-10.

摘要

目的

血管和介入放射学程序的特点是工作人员受到电离辐射的高度暴露。本研究评估了血管放射学和机械血栓切除术过程中医疗人员接触电离辐射的情况。

材料和方法

在血管放射学程序期间,分析了参与程序的 4 组工作人员的暴露情况,即主要手术医生、助理医生、无菌护士和护士。使用热释光剂量计进行电离辐射暴露测量。

结果

在个别组中,1 次治疗的登记有效剂量分别为:平均值(M)±标准差(SD)75±15 μSv、24±5 μSv、13±3 μSv 和 8±2 μSv。在机械血栓切除术期间,手术医生接受的有效剂量为 M±SD 9±2 μSv。在血管放射学程序中,手术医生和协助手术的医生的晶状体当量剂量分别为 M±SD 1419±285 μSv 和 987±198 μSv,双手(包括左手和右手)的当量剂量分别为 M±SD 4605±930 μSv、1420±284 μSv、1898±380 μSv 和 1371±274 μSv。

结论

如果在血管放射学程序中不应用放射防护优化原则,则可能超过允许剂量限值和相当于晶状体和手部剂量的操作限值。在血管放射学程序中暴露的程度与使用放射性氟标记的葡萄糖的核医学程序相似。国际职业医学与环境卫生杂志。2024;37(4):403-10。

相似文献

本文引用的文献

6
Occupational dose in interventional radiology procedures.介入放射学操作中的职业剂量。
AJR Am J Roentgenol. 2013 Jan;200(1):138-41. doi: 10.2214/AJR.11.8455.
7
Thermoluminescence in medical dosimetry.医学剂量测定中的热释光
Appl Radiat Isot. 2012 Dec;71 Suppl:30-4. doi: 10.1016/j.apradiso.2012.04.018. Epub 2012 Apr 30.
8
Risk of radiation exposure during endovascular aortic repair.血管内主动脉修复术的辐射暴露风险。
Eur J Vasc Endovasc Surg. 2012 Apr;43(4):393-7. doi: 10.1016/j.ejvs.2011.12.031. Epub 2012 Jan 21.
9
Minimizing radiation exposure to the vascular surgeon.尽量减少血管外科医生的辐射暴露。
J Vasc Surg. 2012 Mar;55(3):799-805. doi: 10.1016/j.jvs.2011.08.055. Epub 2011 Nov 10.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验