电极组合对气导性眼前庭诱发肌源性电位频率调谐特性的影响

Effect of Electrode Montage on Frequency Tuning Properties of Air-Conducted Ocular Vestibular-Evoked Myogenic Potential.

作者信息

Raveendran Rajesh Kumar, Singh Niraj Kumar

机构信息

Department of Audiology, All India Institute of Speech and Hearing, Manasagangothri, Mysuru 570006, India.

出版信息

Ear Hear. 2025;46(1):71-82. doi: 10.1097/AUD.0000000000001560. Epub 2024 Aug 13.

Abstract

OBJECTIVES

The use of a 500 Hz tone burst over other frequencies was adopted for the clinical recording of ocular vestibular-evoked myogenic potential (oVEMP) on the basis that this stimulus frequency produces larger response amplitudes (frequency tuning) than the other frequencies. However, the possibility of reflex contamination due to a spatially displaced reference electrode from the muscle of the response origin raises questions about using an infraorbital (IO) montage. Nonetheless, the belly-tendon (BT) montage, which places both the recording electrodes over the inferior oblique muscle, increases the chances of obtaining a response with greater contribution from the inferior oblique muscle. However, whether this response continues to show the frequency tuning to 500 Hz is not known. Therefore, the present study aimed to examine the frequency tuning of oVEMP using various electrode montages.

DESIGN

Thirty-eight young adults underwent simultaneous oVEMP recording from IO, BT, chin-referenced, and sternum-referenced electrode montages in response to 250, 500, 750, 1000, 1500, 2000, 3000, and 4000 Hz tone bursts.

RESULTS

The frequency tuning most often coincided with a 750-Hz tone burst irrespective of the montage, with the BT montage exhibiting significantly higher response rates and larger peak to peak amplitudes than other montages ( p < 0.008). Further, there was a "substantial" agreement on frequency tuning between BT and IO montages.

CONCLUSIONS

With better response rates and response amplitudes yet similar frequency tuning to the IO montage, the BT montage can be a better option for the clinical recording of oVEMP across frequencies.

摘要

目的

临床上记录眼前庭诱发肌源性电位(oVEMP)时采用500 Hz短纯音而非其他频率,是基于该刺激频率比其他频率产生更大的反应幅度(频率调谐)。然而,由于参考电极相对于反应起源肌肉的空间移位可能导致反射污染,这引发了关于使用眶下(IO)导联的疑问。尽管如此,将记录电极都置于下斜肌上的肌腹-肌腱(BT)导联,增加了获得来自下斜肌更大贡献的反应的机会。然而,这种反应是否继续表现出对500 Hz的频率调谐尚不清楚。因此,本研究旨在使用各种电极导联检查oVEMP的频率调谐。

设计

38名年轻成年人在响应250、500、750、1000、1500、2000、3000和4000 Hz短纯音时,同时采用IO、BT、下颌参考和胸骨参考电极导联记录oVEMP。

结果

无论采用何种导联,频率调谐最常与750 Hz短纯音一致,BT导联的反应率和峰峰值幅度均显著高于其他导联(p < 0.008)。此外,BT和IO导联在频率调谐方面存在“实质性”一致性。

结论

BT导联具有更好的反应率和反应幅度,且频率调谐与IO导联相似,可作为跨频率临床记录oVEMP的更好选择。

相似文献

1
Effect of Electrode Montage on Frequency Tuning Properties of Air-Conducted Ocular Vestibular-Evoked Myogenic Potential.
Ear Hear. 2025;46(1):71-82. doi: 10.1097/AUD.0000000000001560. Epub 2024 Aug 13.
3
Electrode Montage Induced Changes in Air-Conducted Ocular Vestibular-Evoked Myogenic Potential.
Ear Hear. 2024;45(1):227-238. doi: 10.1097/AUD.0000000000001419. Epub 2023 Aug 23.
5
The effect of electrode positioning on the ocular vestibular evoked myogenic potential to air-conducted sound.
Clin Neurophysiol. 2013 Jun;124(6):1232-6. doi: 10.1016/j.clinph.2012.11.019. Epub 2013 Jan 18.
8
Normal characteristics of the ocular vestibular evoked myogenic potential.
J Am Acad Audiol. 2011 Apr;22(4):222-30. doi: 10.3766/jaaa.22.4.5.
10
Electrode montage and gaze effects on ocular vestibular evoked myogenic potentials (oVEMPs).
Clin Neurophysiol. 2016 Aug;127(8):2846-2854. doi: 10.1016/j.clinph.2016.05.365. Epub 2016 Jun 8.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验