Radiation exposure during simulated equine head and limb fan beam standing computed tomography appears safe for personnel using lead shielding.

作者信息

Veitch Kaylynn E, Szczykutowicz Timothy P, Brounts Sabrina H, Ergun David L, Muir Peter, Loeber Samantha J

机构信息

1Department of Surgical Sciences, School of Veterinary Medicine, University of Wisconsin-Madison, Madison, WI.

4Department of Biomedical Engineering, College of Engineering, University of Wisconsin-Madison, Madison, WI.

出版信息

J Am Vet Med Assoc. 2024 Sep 20;263(1):63-70. doi: 10.2460/javma.24.06.0424. Print 2025 Jan 1.

DOI:10.2460/javma.24.06.0424
PMID:39305927
Abstract

OBJECTIVE

To evaluate the radiation dose to personnel locations during simulated head and limb scans with a novel equine standing CT (sCT) system.

METHODS

Measurements were made with the use of a helical fan beam sCT system (Equina; Asto CT Inc). Scatter radiation was measured in different positions in the sCT room to mimic the location of the control operator, horse handler, and lead rope handler during simulated equine head and limb imaging. Operator/handler dose was quantified at each location using entrance air kerma measured with a spherical ionization chamber and electrometer.

RESULTS

Radiation dose to the control operator, horse handler, and lead rope handler locations wearing a lead apron during simulated head imaging was 13.3, 3.5, and 6.8 µGy, respectively. Radiation dose to the control operator location wearing a lead apron was 1.3 µGy, and dose to the lead rope handler location wearing a lead apron was 0.2 and 5.4 µGy during simulated pelvic limb and thoracic limb imaging, respectively.

CONCLUSIONS

With the more widespread clinical use of equine sCT units in clinical practice, there is concern for increased risk of radiation exposure to personnel who stay in the sCT room during scanning. The control operator location had the highest dose during simulated head imaging, and the lead rope handler location in thoracic limb sCT had the highest dose during simulated limb imaging. Limiting the number of personnel in the sCT room, rotating personnel between handler positions, increasing operator distance from the scanner, and using lead shields and eyeglasses are recommended.

CLINICAL RELEVANCE

Our findings suggest that scanning large numbers of horses per year with the Asto CT Equina would not lead to occupational radiation exposure above the recommended safe threshold for handlers using lead shields and eyeglasses.

摘要

相似文献

1
Radiation exposure during simulated equine head and limb fan beam standing computed tomography appears safe for personnel using lead shielding.
J Am Vet Med Assoc. 2024 Sep 20;263(1):63-70. doi: 10.2460/javma.24.06.0424. Print 2025 Jan 1.
2
Is lead shielding of patients necessary during fluoroscopic procedures? A study based on kyphoplasty.在透视检查过程中对患者进行铅屏蔽是否必要?一项基于椎体后凸成形术的研究。
Skeletal Radiol. 2018 Jan;47(1):37-43. doi: 10.1007/s00256-017-2756-9. Epub 2017 Aug 18.
3
Estimated operator exposure for hand holding portable X-ray units during imaging of the equine distal extremity.
Vet Radiol Ultrasound. 2011 Mar-Apr;52(2):121-4. doi: 10.1111/j.1740-8261.2010.01754.x. Epub 2010 Oct 7.
4
The effectiveness of a free-standing lead-shield in reducing spine surgeon radiation exposure during intraoperative 3-dimensional imaging.独立式铅屏风在减少脊柱外科医生术中三维成像时辐射暴露中的有效性。
Spine J. 2020 Oct;20(10):1685-1691. doi: 10.1016/j.spinee.2020.05.099. Epub 2020 May 20.
5
Radiation exposure to operating room personnel and patients during endovascular procedures.血管内手术过程中手术室人员和患者的辐射暴露。
J Vasc Surg. 2013 Sep;58(3):702-9. doi: 10.1016/j.jvs.2013.02.032. Epub 2013 Jun 28.
6
A randomized study comparing the use of a pelvic lead shield during trans-radial interventions: Threefold decrease in radiation to the operator but double exposure to the patient.一项比较经桡动脉介入治疗期间使用盆腔铅屏蔽的随机研究:术者辐射减少三倍,但患者辐射暴露增加一倍。
Catheter Cardiovasc Interv. 2015 Jun;85(7):1164-70. doi: 10.1002/ccd.25777. Epub 2015 Feb 3.
7
Disposable, lightweight shield decreases operator eye and brain radiation dose when attached to safety eyewear during fluoroscopically guided interventions.一次性、轻便的防护屏,在荧光透视引导介入治疗时附在安全眼镜上,可降低操作人员眼部和脑部的辐射剂量。
J Vasc Surg. 2022 Jun;75(6):2047-2053. doi: 10.1016/j.jvs.2021.11.067. Epub 2021 Dec 17.
8
Not all lightweight lead aprons and thyroid shields are alike.并非所有的轻便型铅围裙和甲状腺防护围领都一样。
J Vasc Surg. 2019 Jul;70(1):246-250. doi: 10.1016/j.jvs.2018.07.055. Epub 2018 Oct 3.
9
Effects of lead shielding on gamma radiation scatter energy spectrum during equine bone scintigraphy.铅屏蔽对马骨闪烁扫描术中γ射线散射能谱的影响。
J S Afr Vet Assoc. 2024 Dec;95(2):63-70. doi: 10.36303/JSAVA.546. Epub 2024 Aug 29.
10
Radiation brain dose to vascular surgeons during fluoroscopically guided interventions is not effectively reduced by wearing lead equivalent surgical caps.血管外科医师在接受透视引导介入时,即使佩戴含铅当量的手术帽,脑部所受辐射剂量也不会有效降低。
J Vasc Surg. 2018 Aug;68(2):567-571. doi: 10.1016/j.jvs.2017.12.054. Epub 2018 Mar 12.

引用本文的文献

1
Equine Standing Multidetector Computed Tomography of the Distal Thoracic Limb and Tarsus Has a Lower Cumulative Radiation Dose than Digital Radiography.马胸部远端肢体和跗关节的站立位多排螺旋计算机断层扫描的累积辐射剂量低于数字X线摄影。
Vet Radiol Ultrasound. 2025 Jul;66(4):e70049. doi: 10.1111/vru.70049.