Single-piece Foldable Intraocular Lenses versus Three-piece Intraocular Lenses in the Sulcus following Posterior Capsular Rupture in a Philippine Tertiary Hospital.

作者信息

Torrefranca Aramis B, Florcruz Nilo Vincent Dg, Carino Noel S, Kho Richard C

机构信息

Department of Ophthalmology and Visual Sciences, Philippine General Hospital, University of the Philippines Manila, Manila, Philippines.

Department of Ocular Health, Governor Celestino Gallares Memorial Medical Center, Tagbilaran City, Bohol, Philippines.

出版信息

Acta Med Philipp. 2024 Aug 30;58(15):67-73. doi: 10.47895/amp.vi0.7960. eCollection 2024.

Abstract

OBJECTIVE

Successful intraocular lens (IOL) placement in cataract surgery is synonymous with the IOL being placed in the capsular bag. When the capsular bag is violated, the ciliary sulcus becomes an option to approximate an in- the-bag position. Studies report that single-piece foldable acrylic (SPA) IOLs are a poor choice for the sulcus. This study aimed to report the visual outcomes and complications of sulcus placement of single-piece intraocular lenses and three-piece intraocular lenses, and compare the design and characteristics to the occurrences of complications.

METHODS

The medical records of patients were retrospectively reviewed in a single center from 2016-2019.

RESULTS

A total of 245 eyes from 237 patients were included in the study with a mean age of 61 years and male predominance. Majority of sulcus implantation occurred during phacoemulsification (87%). Around 82% (n=202) were implanted with single-piece IOLs and 18% (n=43) were three-piece IOLs. Best corrected distance visual acuity (BCDVA) was 20/20 after six months for both groups. Comparison between two groups showed no superiority with each other. Complications notable were elevated intraocular pressure, corneal edema, loss of IOL centration, and pigment dispersion. Smaller optic diameter and overall length predispose to higher probabilities of loss of centration. Pliability, hydrophobicity/hydrophilicity, and material do not correlate with postoperative complications. There were significantly higher numbers of pigment dispersions in IOLs with square-edged design.

CONCLUSIONS

In conclusion, visual outcomes remain equally excellent for both single-piece and three-piece groups. In contrast, there were more notable complications in single-piece group. Loss of centration tends to occur more with mean optic diameters lower than or equal to 5.50 mm and an overall length of less than 12.50 mm or lower. While appropriate for the capsular bag, square-edged designs were found to be inappropriate for the sulcus. The retrospective design does not allow strong inferences hence caution should be taken in correlating results.

摘要

目的

白内障手术中人工晶状体(IOL)的成功植入等同于将IOL植入囊袋内。当囊袋被破坏时,睫状沟成为接近囊袋内位置的一种选择。研究报告称,单片可折叠丙烯酸酯(SPA)IOL不适合植入睫状沟。本研究旨在报告单片式人工晶状体和三片式人工晶状体植入睫状沟的视觉效果和并发症,并比较其设计和特性与并发症发生率之间的关系。

方法

对2016年至2019年在单一中心就诊患者的病历进行回顾性分析。

结果

本研究共纳入237例患者的245只眼,平均年龄61岁,男性居多。大多数睫状沟植入发生在超声乳化手术期间(87%)。约82%(n = 202)植入的是单片式IOL,18%(n = 43)是三片式IOL。两组患者术后6个月的最佳矫正远视力(BCDVA)均为20/20。两组之间的比较显示彼此无优势。值得注意的并发症有眼压升高、角膜水肿、IOL中心定位丧失和色素播散。较小的光学直径和总长度更容易导致中心定位丧失。柔韧性、疏水性/亲水性和材料与术后并发症无关。方形边缘设计的IOL色素播散的数量明显更多。

结论

总之,单片式和三片式人工晶状体组的视觉效果同样出色。相比之下,单片式组的并发症更明显。当平均光学直径小于或等于5.50 mm且总长度小于12.50 mm或更短时,更容易发生中心定位丧失。方形边缘设计虽然适用于囊袋,但不适合睫状沟。本研究为回顾性设计,无法得出有力推断,因此在关联结果时应谨慎。