Suppr超能文献

Atmospheric concentrations of per- and polyfluoroalkyl substances and their emissions at a waste recycling facility producing refuse-derived paper and plastics densified fuel.

作者信息

Kuribara Isamu, Motoki Toshiyuki, Matsukami Hidenori, Takahashi Yusuke, Kuramochi Hidetoshi

机构信息

Graduate School of Frontier Sciences, The University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8564, Japan; Chemicals Evaluation and Research Institute, Japan (CERI), 1600 Shimotakano, Sugito-machi, Kitakatsushika-gun, Saitama 345-0043, Japan.

Center for Material Cycles and Waste Management Research, National Institute for Environmental Studies (NIES), 16-2 Onogawa, Tsukuba, Ibaraki 305-8506, Japan.

出版信息

Sci Total Environ. 2024 Dec 1;954:176456. doi: 10.1016/j.scitotenv.2024.176456. Epub 2024 Sep 21.

Abstract

To better understand the types and concentrations of per- and polyfluoroalkyl substances (PFAS) emitted into the air from waste recycling facilities that produce refuse-derived paper and plastics densified fuel (RPF) from industrial waste, we conducted an air sampling campaign at a waste recycling facility in Japan. Both passive and active air sampling were conducted, and the samples collected were used to quantify the PFAS emitted into the air during the production of RPF. Overall, few ionic PFAS were detected in the air at the facility; however, high levels of neutral PFAS (8.21-53.4 ng/m; 20.7-130 pmol/m) were measured in the air near the heat molding machines. The two neutral PFAS detected at the highest concentrations were 6:2 fluorotelomer alcohol and 6:2 fluorotelomer methacrylate, which are currently unregulated under the Stockholm Convention, suggesting that product manufacturers have shifted away from using regulated PFAS. Small amounts of regulated PFAS such as 8:2 fluorotelomer methacrylate and 8:2 fluorotelomer acrylate were measured in some parts of the facility. Analysis of the concentrations of PFAS in the exhaust gas from the heat molding machines revealed neutral PFAS concentrations (537-2160 ng/m; 1350-5040 pmol/m) that were 1-2 orders of magnitude higher than those in the surrounding indoor air. The total emission of neutral PFAS from the facility to the environment was estimated to be 0.066-0.260 g/day (0.168-0.607 mmol/day), depending on whether air volume discharged as exhaust gas or as indoor ventilation was considered. A contribution analysis of the emissions revealed that treating the exhaust gas from the heat molding machines, which constitutes over 94 % of the total emissions, is very effective at reducing PFAS emissions from the facility.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验