生物诱导性胶原蛋白植入物有望改善肩袖愈合:一项系统评价。

Bioinductive Collagen Implant Has Potential to Improve Rotator Cuff Healing: A Systematic Review.

作者信息

Hurley Eoghan T, Twomey-Kozack Jack, Doyle Tom R, Meyer Lucy E, Meyer Alex M, Lorentz Samuel G, Bradley Kendall E, Dickens Jonathan F, Klifto Christopher S

机构信息

Department of Orthopaedic Surgery, Duke University, Durham, North Carolina, USA.

Department of Orthopaedic Surgery, Duke University, Durham, North Carolina, USA.

出版信息

Arthroscopy. 2025 Feb;41(2):333-342.e2. doi: 10.1016/j.arthro.2024.09.028. Epub 2024 Sep 24.

Abstract

PURPOSE

To systematically review the literature to evaluate the clinical studies on bioinductive collagen implant (BCI) for the treatment of rotator cuff tears.

METHODS

A literature search of MEDLINE, Embase, and the Cochrane Library was performed based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Clinical studies reporting BCI for rotator cuff tears were included. Quantitive and qualitative data were evaluated.

RESULTS

A total of 21 studies were included. In patients with full-thickness tears, 7 of the 8 studies with pre- to postoperative American Shoulder and Elbow Surgeons (ASES) scores demonstrated statistically significant improvements in mean pre- to postoperative ASES scores, with 75% to 100% of patients meeting the minimal clinically important difference. In those with partial-thickness tears, 7 of the 8 studies with pre- to postoperative ASES scores demonstrated statistically significant improvements in mean pre- to postoperative ASES scores, with 54.4% to 100% of patients meeting the minimal clinically important difference. For studies that quantified percent increases in tendon thickness, the reported increases ranged from 13% to 44% in full-thickness tears and 14% to 60% in partial-thickness tears. Six studies evaluated rotator cuff retears after BCI treatment in the full-thickness cohort, with rates reported ranging from 0% to 9%. Five studies evaluated rotator cuff retears after BCI treatment in the partial-thickness cohort, with rates reported ranging from 0% to 18%. Two of the included studies found that BCI was cost-effective due to the increased tendon healing, with cost savings of $5,338 to $13,061 per healed rotator cuff tendon.

CONCLUSIONS

The literature on rotator cuff tear augmentation with BCI has shown consistently reported good results. Additionally, there was evidence of low retear rates and consistently improved tendon thickness with BCI, with 2 randomized controlled trials showing improved tendon healing with BCI. However, there appears to be a higher rate of adhesive capsulitis reported.

LEVEL OF EVIDENCE

Level IV, systematic review of Level I, III, and IV studies.

摘要

目的

系统回顾文献,评估生物诱导胶原蛋白植入物(BCI)治疗肩袖撕裂的临床研究。

方法

根据系统评价和Meta分析的首选报告项目指南,对MEDLINE、Embase和Cochrane图书馆进行文献检索。纳入报告BCI治疗肩袖撕裂的临床研究。对定量和定性数据进行评估。

结果

共纳入21项研究。在全层撕裂患者中,8项术前至术后采用美国肩肘外科医师(ASES)评分的研究中有7项显示术前至术后ASES平均评分有统计学显著改善,75%至100%的患者达到最小临床重要差异。在部分层撕裂患者中,8项术前至术后采用ASES评分的研究中有7项显示术前至术后ASES平均评分有统计学显著改善,54.4%至100%的患者达到最小临床重要差异。对于量化肌腱厚度增加百分比的研究,全层撕裂中报告的增加范围为13%至44%,部分层撕裂中为14%至60%。6项研究评估了全层队列中BCI治疗后的肩袖再撕裂情况,报告的发生率为0%至9%。5项研究评估了部分层队列中BCI治疗后的肩袖再撕裂情况,报告的发生率为0%至18%。纳入的两项研究发现,由于肌腱愈合增加,BCI具有成本效益,每例愈合的肩袖肌腱节省成本5338美元至13061美元。

结论

关于BCI增强肩袖撕裂修复的文献一致报道了良好的结果。此外,有证据表明BCI的再撕裂率低,肌腱厚度持续改善,2项随机对照试验显示BCI可改善肌腱愈合。然而,报告的粘连性关节囊炎发生率似乎较高。

证据级别

IV级,对I、III和IV级研究的系统评价。