模拟口腔内调改对渐变多层整体式氧化锆颜色和半透明度的影响

Effect of simulated intraoral adjustment on the color and translucency of gradient multilayered monolithic zirconia.

作者信息

Ghanem Reham, Adel Ahmed, Al-Zordk Walid

机构信息

Graduate student, Department of Fixed Prosthodontics, Mansoura University, Mansoura, Egypt.

Lecturer, Department of Fixed Prosthodontics, Mansoura University, Mansoura, Egypt.

出版信息

J Prosthet Dent. 2024 Dec;132(6):1313.e1-1313.e8. doi: 10.1016/j.prosdent.2024.08.025. Epub 2024 Sep 26.

Abstract

STATEMENT OF PROBLEM

The use of multilayered monolithic zirconia ceramics is becoming popular because it simplifies the production of esthetic restorations. The effect of clinical adjustment on the optical properties of these ceramics, especially strength-gradient zirconia, remains unclear.

PURPOSE

The purpose of this in vitro study was to evaluate the color and translucency of gradient multilayered zirconia brands after grinding and polishing.

MATERIAL AND METHODS

Sixty 10×10×1-mm monolithic zirconia specimens were milled from 6 zirconia brands (Ceramill Zolid HT White, Ceramill Zolid HT Preshade, Ceramill Zolid FX Multicolor, VITA YZ XT Multicolor, IPS e.max ZirCAD Prime, and KATANA YML). The zirconia specimens were milled to include all layers of A2 preshaded multilayered zirconia blanks (A2 shade) except Ceramill Zolid HT White and Ceramill Zolid HT Preshade. Ceramill Zolid HT White specimens were milled from a white zirconia blank with subsequent shading. The color coordinates and the relative translucency parameter after glazing and after grinding and polishing were determined with a reflectance spectrophotometer, and the relative translucency parameter and contrast ratio were measured. The differences in color and translucency were calculated. The data were analyzed using 2-way ANOVA and 1-way ANOVA tests followed by the post hoc Tukey test (α=.05).

RESULTS

Statistically significant changes (P<.001) in the color coordinates measured before and after grinding and polishing were detected for each zirconia brand except for the KATANA YML that showed no significant difference (P=.686) in lightness. The highest color difference after grinding and polishing was detected in group KATANA YML. The 2-way ANOVA test showed a statistically significant interaction (P<.001) between the zirconia brand and the grinding and polishing regarding the relative translucency parameter. The zirconia brand had a significant impact on the relative translucency parameter before and after grinding and polishing (both P<.001).

CONCLUSIONS

Except for KATANA YML, the color change in multilayered zirconia after clinical adjustment with polishing was not beyond the clinically acceptable limit of the color difference. Although clinical adjustment with polishing reduced the translucency of gradient zirconia, the change in translucency was below the clinically detectable threshold value of the translucency difference.

摘要

问题陈述

多层整体式氧化锆陶瓷的应用日益广泛,因为它简化了美观修复体的制作。临床调改对这些陶瓷,尤其是强度梯度氧化锆的光学性能的影响尚不清楚。

目的

本体外研究的目的是评估研磨和抛光后梯度多层氧化锆品牌的颜色和半透明度。

材料与方法

从6种氧化锆品牌(Ceramill Zolid HT White、Ceramill Zolid HT Preshade、Ceramill Zolid FX Multicolor、VITA YZ XT Multicolor、IPS e.max ZirCAD Prime和KATANA YML)中铣削出60个10×10×1mm的整体式氧化锆试样。除Ceramill Zolid HT White和Ceramill Zolid HT Preshade外,将氧化锆试样铣削成包含A2预染色多层氧化锆坯体(A2色)的所有层。Ceramill Zolid HT White试样由白色氧化锆坯体铣削而成,随后进行染色。使用反射分光光度计测定上釉后以及研磨和抛光后的颜色坐标和相对半透明度参数,并测量相对半透明度参数和对比度。计算颜色和半透明度的差异。使用双向方差分析和单向方差分析测试,随后进行事后Tukey检验(α = 0.05)对数据进行分析。

结果

除KATANA YML在明度上无显著差异(P = 0.686)外,每个氧化锆品牌在研磨和抛光前后测量的颜色坐标均有统计学显著变化(P < 0.001)。KATANA YML组在研磨和抛光后的颜色差异最大。双向方差分析测试显示,在相对半透明度参数方面,氧化锆品牌与研磨和抛光之间存在统计学显著交互作用(P < 0.001)。氧化锆品牌对研磨和抛光前后的相对半透明度参数均有显著影响(均P < 0.001)。

结论

除KATANA YML外,多层氧化锆经抛光临床调改后的颜色变化未超出临床上可接受的色差限度。虽然抛光临床调改降低了梯度氧化锆的半透明度,但半透明度的变化低于临床上可检测到的半透明度差异阈值。