Suppr超能文献

二维超声心动图右心比值评估犬右心大小:参考范围和可重复性。

Two-dimensional echocardiographic right heart ratios for assessment of right heart size in dogs: Reference intervals and reproducibility.

机构信息

Department of Clinical Sciences, College of Veterinary Medicine & Biomedical Sciences, Colorado State University, Fort Collins, Colorado, USA.

出版信息

J Vet Intern Med. 2024 Nov-Dec;38(6):3005-3015. doi: 10.1111/jvim.17159. Epub 2024 Sep 30.

Abstract

BACKGROUND

Reference intervals for simple body weight-independent measurements of right heart size and function are limited.

OBJECTIVES

Generate reference intervals for measurements of right heart size indexed to the long-axis aortic valve diameter (AoD) or corresponding left heart structure (right heart ratios) and describe the reproducibility of these indices.

ANIMALS

Ninety healthy adult dogs of variable body weight.

METHODS

Prospective study. All dogs underwent an echocardiogram performed by the same operator. Numerous linear 2-dimensional measurements of right heart size and function from different imaging planes were performed. Eight dogs underwent repeated echocardiograms by the same operator on 3 different days, and 3 different operators performed repeated echocardiograms on the same day. Reference intervals were generated using the Clinical Laboratory Standards Institute method. Reproducibility was quantitated using coefficients of variation (CVs) and reproducibility coefficients.

RESULTS

Reference intervals for right heart ratios were generated and allow simple assessments of right heart size and function that do not require a scaling exponent or body weight table. Right heart ratios did not show clinically relevant associations with body weight. All CVs were <22.6%. In general, CVs for right heart measurements indexed to AoD were lower compared with right heart measurements indexed to the corresponding left heart structure.

CONCLUSIONS AND CLINICAL IMPORTANCE

Reference intervals for simple body weight-independent right heart ratios are available to help detect abnormalities of right heart size and function. Reproducibility coefficients might be useful to help identify meaningful changes in right heart size during serial evaluations.

摘要

背景

简单的体重独立的右心大小和功能测量的参考区间是有限的。

目的

生成右心大小与升主动脉瓣环直径(AoD)或相应的左心结构(右心比值)指数相关的测量参考区间,并描述这些指数的可重复性。

动物

90 只体重不同的健康成年犬。

方法

前瞻性研究。所有犬均由同一位操作者进行超声心动图检查。从不同的成像平面进行了大量的右心大小和功能的线性 2 维测量。8 只犬由同一位操作者在 3 个不同的日子进行了重复的超声心动图检查,而 3 位不同的操作者在同一天进行了重复的超声心动图检查。参考区间是使用临床实验室标准协会方法生成的。使用变异系数(CVs)和再现性系数来量化可重复性。

结果

生成了右心比值的参考区间,允许简单评估右心大小和功能,而不需要缩放指数或体重表。右心比值与体重没有临床相关的关联。所有 CVs 均<22.6%。一般来说,AoD 指数化的右心测量的 CVs 低于相应的左心结构指数化的右心测量的 CVs。

结论和临床意义

简单的体重独立的右心比值的参考区间可用于帮助检测右心大小和功能的异常。再现性系数可能有助于帮助识别在连续评估中右心大小的有意义的变化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fb0b/11586550/18e1112754b8/JVIM-38-3005-g002.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验