Effects of curing lights on polymerization shrinkage of composite attachments in clear aligner treatment: A microcomputed tomography study.

作者信息

Ocak Irmak, Aksu Muge

机构信息

Department of Orthodontics, Faculty of Dentistry, Hacettepe University, Ankara, Turkey.

Private practice, Ankara, Turkey.

出版信息

Am J Orthod Dentofacial Orthop. 2025 Jan;167(1):63-72. doi: 10.1016/j.ajodo.2024.08.012. Epub 2024 Oct 2.

Abstract

INTRODUCTION

This study aimed to investigate the polymerization shrinkage of composite attachments and changes in attachment templates during bonding in clear aligner treatments.

METHODS

A total of 24 extracted teeth were divided into 4 groups, and plaster models were digitized. Attachment templates were produced with beveled attachments on premolars and rectangular attachments on molars. Polymerizations used a halogen curing light (800 milliwatts per square centimeter [mW/cm] for 20 seconds) and light-emitting diode (LED) curing light in 3 modes (1000 mW/cm for 20 seconds, 1000 mW/cm for 10 seconds, and 3200 mW/cm for 3 seconds). The curing distance was 5 mm, and temperature changes were recorded with a thermal camera. Microcomputed tomography scanning measured volumetric and linear attachments before and after polymerization. Statistical analyses employed a 1-way analysis of variance with Bonferroni corrected Tukey post-hoc for multiple comparisons and the Kruskal-Wallis test for temperature change.

RESULTS

Significant differences (P <0.001) were found in temperature among curing lights. The highest temperature was in the LED unit-extra mode, and the lowest was in the halogen curing unit. The LED unit for 20 seconds caused the highest temperature change. A significant difference (P = 0.048) in occlusal attachment length was found between the LED unit for 20 seconds and the LED unit-extra mode. Polymerization resulted in increased attachment template thickness across all groups, with significant changes noted in the halogen unit, LED unit for 20 seconds, and LED unit-extra mode.

CONCLUSIONS

Temperature generated during polymerization varied between halogen and LED curing lights. Significant differences were found in attachment length at the occlusal level and template thickness postpolymerization. Preferences in attachment bonding protocols may affect the clinical precision of clear aligner treatments.

摘要

引言

本研究旨在调查在透明矫治器治疗中复合附件的聚合收缩以及粘结过程中附件模板的变化。

方法

将总共24颗拔除的牙齿分为4组,并对石膏模型进行数字化处理。制作的附件模板在前磨牙上采用斜面附件,在磨牙上采用矩形附件。聚合过程使用卤素固化灯(每平方厘米800毫瓦[mW/cm],照射20秒)和发光二极管(LED)固化灯,有3种模式(1000 mW/cm,照射20秒;1000 mW/cm,照射10秒;3200 mW/cm,照射3秒)。固化距离为5毫米,并用热成像仪记录温度变化。聚合前后通过微型计算机断层扫描测量附件的体积和线性尺寸。统计分析采用单因素方差分析,并使用Bonferroni校正的Tukey事后检验进行多重比较,以及使用Kruskal-Wallis检验分析温度变化。

结果

发现不同固化灯之间的温度存在显著差异(P<0.001)。最高温度出现在LED单元-额外模式下,最低温度出现在卤素固化单元中。LED单元照射20秒导致的温度变化最大。在LED单元照射20秒和LED单元-额外模式之间,发现咬合附件长度存在显著差异(P = 0.048)。聚合导致所有组的附件模板厚度增加,在卤素单元、LED单元照射20秒和LED单元-额外模式下有显著变化。

结论

卤素固化灯和LED固化灯在聚合过程中产生的温度不同。在咬合水平的附件长度以及聚合后模板厚度方面发现了显著差异。附件粘结方案的选择可能会影响透明矫治器治疗的临床精度。