Suppr超能文献

不同CAD-CAM材料的咬合贴面修复磨牙的抗折性能受修复体设计的影响:一项体外研究。

Effect of preparation design on fracture resistance of molars restored with occlusal veneers of different CAD-CAM materials: an in vitro study.

作者信息

Taha Ahmed Ismail, Hafez Mona Elshirbini

机构信息

Prosthodontic Department, Faculty of Dentistry, Kafr Al Sheikh University, Mubark Road, 33511 Kafr Abu Tabl, Kafrelsheikh Governorate, Kafr Al Sheikh, 6860404, Egypt.

Conservative Department, Faculty of Dentistry, Kafr Al Sheikh University, Kafr Al Sheikh, Egypt.

出版信息

BMC Oral Health. 2024 Oct 1;24(1):1168. doi: 10.1186/s12903-024-04904-4.

Abstract

BACKGROUND

Occlusal veneer had been evaluated for mechanical properties using lithium disillicate. However, studies evaluating the mechanical properties of occlusal veneer with different preparation designs and ceramic materials are lacking. So, this in vitro study aimed to evaluate the fracture resistance of occlusal veneers with two designs fabricated from two different ceramic materials.

MATERIAL AND METHODS

Fourty mandibular third molars were distributed to 2 groups (n = 20) according to preparation design: group (O) anatomical occlusal reduction and group (OA) anatomical occlusal and 1 mm axial reduction. Each group was additionally subdivided into two subgroups (n = 10) according to ceramic materials; in subgroup X, lithium disilicate (e.max CAD, Ivoclar AG, Schaan, Liechtenstein) was used, and in subgroup S, zirconia-reinforced lithium silicate (ZLS) (Vita Suprinity, VitaZahnfabrik, Bad Säckingen, Germany) was used. All specimens were cemented with a light-cure resin cement (Choice 2, Bisco, Schaumburg, USA). 5000 thermocycles were applied to all specimens with both temperatures of 5 °C and 55 °C in two water baths; the dwell time was 30s at each bath, and the transfer time was 10s. Then all specimens were subjected to a fatigue simulation under dynamic loading of 200 N for 250,000 cycles. A universal testing machine (5500R/1123, Instron, Norwood, USA) was used to evaluate the fracture strength with a crosshead speed of 1 mm/min. All data were analyzed statistically by using a two-way ANOVA, and for some violations of assumptions, these results were compared with those obtained by the nonparametric test (Scheirer Ray Hare) (α = 0.05).

RESULTS

A statistically significantly higher fracture resistance in the 'OA' (3389 N) compared to the 'O' (2787 N) group regardless of the ceramic material (P < .001) and a statistically significantly higher fracture resistance in the 'X' (3295 N) compared to the 'S' (2881 N) regardless of the preparation design (P = .015).

CONCLUSIONS

For occlusal veneers, all preparation designs and materials (such as Vita Suprinity and e.max CAD) had clinically acceptable fracture resistance values that were greater than the maximal biting forces. On the other hand, the e.max CAD with occlusal veneer, including axial reduction design, demonstrated the maximum fracture resistance value. Finally, no relationship between fracture strength and mode of failure was found.

摘要

背景

已使用二硅酸锂对咬合贴面的机械性能进行了评估。然而,缺乏评估不同制备设计和陶瓷材料的咬合贴面机械性能的研究。因此,本体外研究旨在评估由两种不同陶瓷材料制成的两种设计的咬合贴面的抗折性。

材料与方法

根据制备设计将40颗下颌第三磨牙分为2组(n = 20):组(O)解剖学咬合面降低组和组(OA)解剖学咬合面及1mm轴向降低组。根据陶瓷材料,每组再细分为两个亚组(n = 10);在亚组X中,使用二硅酸锂(e.max CAD,义获嘉伟瓦登特公司,沙恩,列支敦士登),在亚组S中,使用氧化锆增强硅酸锂(ZLS)(维他灵,维他齿科集团,巴特萨金根,德国)。所有标本均用光固化树脂水门汀(Choice 2,必思科公司,绍姆堡,美国)粘结。在两个水浴中对所有标本施加5000次热循环,温度分别为5°C和55°C;每个水浴中的停留时间为30秒,转移时间为10秒。然后所有标本在200N的动态载荷下进行250,000次循环的疲劳模拟。使用万能试验机(5500R/1123,英斯特朗公司,诺伍德,美国)以1mm/min的十字头速度评估抗折强度。所有数据均使用双向方差分析进行统计学分析,对于一些违反假设的情况,将这些结果与非参数检验(谢勒尔·雷·黑尔检验)获得的结果进行比较(α = 0.05)。

结果

无论陶瓷材料如何,“OA”组(3389N)的抗折性在统计学上均显著高于“O”组(2787N)(P <.001);无论制备设计如何,“X”组(3295N)的抗折性在统计学上均显著高于“S”组(2881N)(P = 0.015)。

结论

对于咬合贴面,所有制备设计和材料(如维他灵和e.max CAD)的抗折性值在临床上均可接受,均大于最大咬合力。另一方面,包括轴向降低设计的e.max CAD咬合贴面表现出最大的抗折性值。最后,未发现抗折强度与失效模式之间的关系。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/8fff/11443832/396171b1d9bc/12903_2024_4904_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验