Abstract

The neutron beam in boron neutron capture therapy (BNCT) exhibits poor directionality and significantly decreasing neutron flux with increasing distance. Therefore, the treatment site must be close to the irradiation aperture. Some patients with head and neck cancer may benefit from a sitting-position setup. The study aim was to evaluate the treatment-positioning accuracy and dose error in sitting patients receiving BNCT. Thirty-two patients with head and neck cancer who underwent sitting-position BNCT at Southern Tohoku BNCT Research Center were included in the study. Horizontal (ΔX) and vertical (ΔY) errors were defined as the displacement between the treatment planning system (TPS) digital reconstructed radiograph and the pre-treatment X-ray image. Using in-house software, image matching was performed. The beam-axial directional (ΔZ) error was compared with the parameters entered into the TPS and the actual pre-treatment measured values. The translational-position error was reflected in the TPS's patient coordinate system with respect to the reference plan. Re-dose calculations were performed to evaluate the effect of positional error on tumor and normal-tissue doses. The [ΔX, ΔY, ΔZ] mean ± 1SD were - 0.40 ± 2.0, 0.30 ± 2.3, and - 1.4 ± 1.5 mm, respectively. The D and D tumor-dose errors were 1.22 % ± 1.44 % and 0.99 % ± 1.63 %, respectively. The D pharyngeal and oral mucosal-dose errors were 0.98 % ± 1.91 % and 1.21 % ± 1.78 %, respectively. The tumor- and normal-tissue dose errors were typically < 5 %. High-precision treatment was feasible in sitting-positioned BNCT.

摘要

硼中子俘获治疗(BNCT)中的中子束方向性差,随着距离的增加,中子通量显著降低。因此,治疗部位必须靠近照射孔径。一些头颈部癌症患者可能受益于坐姿设置。本研究旨在评估接受 BNCT 的坐姿患者的治疗定位准确性和剂量误差。32 例头颈部癌症患者在南部东北 BNCT 研究中心接受坐姿 BNCT,纳入本研究。水平(ΔX)和垂直(ΔY)误差定义为治疗计划系统(TPS)数字重建射线照片与治疗前 X 射线图像之间的位移。使用内部软件进行图像匹配。比较了轴向方向(ΔZ)误差与 TPS 中输入的参数和实际治疗前测量值。平移位置误差反映在 TPS 的患者坐标系中相对于参考计划。重新剂量计算用于评估位置误差对肿瘤和正常组织剂量的影响。[ΔX、ΔY、ΔZ]的平均值±1SD 分别为-0.40±2.0、0.30±2.3 和-1.4±1.5mm。D 和 D 肿瘤剂量误差分别为 1.22%±1.44%和 0.99%±1.63%。D 咽和口腔黏膜剂量误差分别为 0.98%±1.91%和 1.21%±1.78%。肿瘤和正常组织的剂量误差通常<5%。坐姿 BNCT 可以实现高精度治疗。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验