Dahlke H, Dociu N, Thurau K
Handchirurgie. 1979;11(1):3-13.
In a series of experiments on the aorta of the rat, the behaviour of an absorbable monofilament suture VICRYL (Polyglactin 910) was compared to that of a non-absorbable suture ETHILON (Polyamide 6/6). A total of 86 rats was operated upon and examined over a period of 70 days. The report includes a complete description of experimental procedures and techniques used during the operations. The evaluation of the experiments took place after completion of the mechanical, histological and scanning electron microscopical tests. It has been proven that under similar conditions, the 0,2 metric suture VICRYL has adequate tensile strength to withstand the intravascular pressure in a vessel with an outer diameter of approx. 1,5 mm. Aneurysm, stenosis and dehiscence of the anastomosis did not occur. The VICRYL suture showed no reactive processes after a period of 42 days. With the suture ETHILON the inflammation of the media and the hyperplasia of the intima persisted even after 70 days, at the end of the experiment. It is therefore shown in microsurgery, the monofilament absorbable suture VICRYL and the non-absorbable monofilament suture ETHILON are equal in their mechanical qualities, but that the suture VICRYL has by far the better tissue compatibility.
在一系列关于大鼠主动脉的实验中,将可吸收单丝缝线VICRYL(聚乙醇酸910)的性能与不可吸收缝线ETHILON(聚酰胺6/6)的性能进行了比较。总共86只大鼠接受了手术,并在70天的时间里进行了检查。该报告包括对手术过程中使用的实验程序和技术的完整描述。实验评估在机械、组织学和扫描电子显微镜测试完成后进行。已经证明,在类似条件下,0.2毫米规格的VICRYL缝线具有足够的拉伸强度,能够承受外径约为1.5毫米的血管内压力。未出现动脉瘤、狭窄和吻合口裂开的情况。42天后,VICRYL缝线未显示出任何反应过程。使用ETHILON缝线时,即使在实验结束70天后,中膜炎症和内膜增生仍持续存在。因此,在显微外科手术中表明,单丝可吸收缝线VICRYL和不可吸收单丝缝线ETHILON在机械性能方面相当,但VICRYL缝线的组织相容性要远好得多。