Suppr超能文献

一次活检是否足够?使用股外侧肌和比目鱼肌的重复活检重新探讨人类肌肉纤维类型组成的可变性。

Does one biopsy cut it? Revisiting human muscle fiber type composition variability using repeated biopsies in the vastus lateralis and gastrocnemius medialis.

机构信息

Department of Movement and Sports Sciences, Ghent University, Ghent, Belgium.

Department of Physiology, Nutrition and Biomechanics, Åstrand Laboratory, Swedish School of Sport and Health Sciences, Stockholm, Sweden.

出版信息

J Appl Physiol (1985). 2024 Nov 1;137(5):1341-1353. doi: 10.1152/japplphysiol.00394.2024. Epub 2024 Oct 3.

Abstract

Human skeletal muscle fiber type composition varies greatly along the muscle, so one biopsy may not accurately represent the whole muscle. Recommendations on the number of biopsies and fiber counts using immunohistochemistry and whether these findings can be extrapolated to other muscles are lacking. We assessed fiber type composition in the vastus lateralis and gastrocnemius medialis muscles of 40 individuals. Per muscle, we took four biopsy samples from one incision, collecting two samples each from a proximally and distally directed needle. Based on another dataset involving 10 vastus lateralis biopsies per participant ( = 7), we calculated 95% limits of agreement for subsets of biopsies and fiber counts compared with the 10-biopsy average. Average absolute differences in type I fiber proportions between proximal and distal, and between within-needle samples were 6.9 and 4.5 percentage points in the vastus lateralis, and 5.5 and 4.4 percentage points in the gastrocnemius medialis, respectively. The 95% limits of agreement narrowed to ±10 percentage points when 200 fibers from at least three biopsies were analyzed, with minimal improvements with greater fiber counts. Type I fiber proportions in the vastus lateralis and gastrocnemius medialis showed a moderate positive association ( = 0.22; = 0.006; at least 200 fibers in each of three to four samples per muscle). In conclusion, three biopsies with a minimum of 200 counted fibers are required to estimate the vastus lateralis fiber type composition within ±10 percentage points. Even when using these standards, researchers should be cautious when extrapolating muscle fiber type proportions from one muscle to another. Fiber type composition is equally variable in muscle biopsy samples taken from one incision as from multiple incisions. Hence, we propose two biopsies from a single incision-needles directed proximally and distally, and each rotated 180° for cutting a second sample-as a more feasible, less invasive alternative to three biopsies from as many incisions. In addition, we identified the gastrocnemius medialis as a slow-twitch muscle with an average of 64.7% slow fibers.

摘要

人体骨骼肌纤维类型组成在肌肉中差异很大,因此一次活检可能无法准确代表整个肌肉。关于使用免疫组织化学进行活检的数量和纤维计数的建议,以及这些发现是否可以外推到其他肌肉,目前还缺乏相关信息。我们评估了 40 个人的股外侧肌和比目鱼肌的纤维类型组成。每个肌肉我们从一个切口处采集 4 个活检样本,每个样本分别从近端和远端方向的针采集。根据另一项涉及每个参与者 10 个股外侧肌活检的数据集(= 7),我们计算了与 10 个活检平均值相比,活检和纤维计数子集的 95%一致性界限。在股外侧肌中,近端和远端以及针内样本之间的 I 型纤维比例的平均绝对差异分别为 6.9 和 4.5 个百分点,在比目鱼肌中分别为 5.5 和 4.4 个百分点。当分析至少 3 个活检的 200 根纤维时,95%一致性界限缩小到±10 个百分点,随着纤维计数的增加,改善幅度最小。股外侧肌和比目鱼肌的 I 型纤维比例呈中度正相关(= 0.22;= 0.006;每个肌肉的每个样本中至少有 200 根纤维)。总之,需要 3 个活检,每个活检至少有 200 根计数纤维,才能在±10 个百分点内估计股外侧肌的纤维类型组成。即使使用这些标准,研究人员在将肌肉纤维类型比例从一块肌肉外推到另一块肌肉时也应谨慎。从一个切口采集的肌肉活检样本中,纤维类型组成与从多个切口采集的样本一样具有高度可变性。因此,我们建议从一个切口取 2 个活检,针分别向近端和远端方向插入,并旋转 180°以切割第二个样本,作为一种更可行、侵入性更小的替代方案,取代从多个切口取 3 个活检。此外,我们发现比目鱼肌是一种慢肌,平均有 64.7%的慢纤维。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验