Suppr超能文献

康复性肌肉骨骼超声测量枕下肌肉可见横截面积的可靠性

Reliability of Rehabilitative Musculoskeletal Sonography for Measuring the Visible Cross-Sectional Area of Suboccipital Muscles.

作者信息

Masoudi Pezhman, Karimi Noureddin, Abdollahi Iraj, Moravej Saeideh, Tahamtan Arash

机构信息

Physical Therapy, University of Social Welfare and Rehabilitation Sciences, Tehran, IRN.

Medicine, Islamic Azad University of Medical Sciences, Tehran, IRN.

出版信息

Cureus. 2024 Sep 6;16(9):e68772. doi: 10.7759/cureus.68772. eCollection 2024 Sep.

Abstract

Aims The primary aim of this study is to assess the reliability of rehabilitative sonography as a non-invasive imaging technique for measuring the visible cross-sectional area (CSA) of the deep suboccipital muscles. Objectives Objectives involve determining both the intra-rater and inter-rater reliability of sonographic measurements to ensure consistent and reproducible results across different sessions and examiners. The ultimate goal is to validate rehabilitative sonography as a reliable tool for clinical and research applications in the assessment and management of musculoskeletal (MSK) conditions involving the deep suboccipital muscles. Design and setting Seventeen participants, including nine women and eight men without neck or vertebral pain, were evaluated using MSK sonography. The visible CSA of suboccipital muscles was assessed using real-time B-mode sonography in a sitting position with a linear probe (5 cm, 7.5 MHz) aligned perpendicularly to the muscle fibers of the rectus capitis posterior minor (RCPM) in one sonogram and the obliquus capitis inferior (OCI) and rectus capitis posterior major (RCPMJ) in another. Two experienced examiners performed sonography measurements, and the procedure was repeated one hour and again one day later. Results Intra-class correlation coefficient (ICC) values for Examiner 1 were 0.84 and 0.79 for RCPM, 0.84 and 0.71 for RCPMJ, and 0.86 and 0.77 for OCI at the one-hour and one-day repetitions, respectively. ICC values for Examiner 2 were 0.86 and 0.77 for RCPM, 0.77 and 0.86 for RCPMJ, and 0.61 and 0.64 for OCI at the one-hour and one-day repetitions, respectively. Inter-rater ICC values were 0.77 for RCPM, 0.82 for RCPMJ, and 0.68 for OCI. Standard error of measurement (SEM) values for Examiner 1 were 11.63 and 13.92 mm² for RCPM, 10.30 and 7.91 mm² for RCPMJ, and 22.84 and 34.61 mm² for OCI. SEM values for Examiner 2 were 11.82 and 13.40 mm² for RCPM, 11.91 and 7.04 mm² for RCPMJ, and 39.20 and 37.73 mm² for OCI. SEM values between examiners were 13.74 mm² for RCPM, 10.36 mm² for RCPMJ, and 36.03 mm² for OCI. Conclusions These findings suggest that sonography is a reliable method for measuring the CSA of the RCPM, RCPMJ, and OCI muscles, provided that the examiners are well-trained and consistent in their techniques and that the average of three measurements is used.

摘要

目的 本研究的主要目的是评估康复超声检查作为一种非侵入性成像技术用于测量枕下深层肌肉可见横截面积(CSA)的可靠性。目标 目标包括确定超声测量的同一检查者内部和不同检查者之间的可靠性,以确保在不同检查时段和不同检查者之间获得一致且可重复的结果。最终目标是验证康复超声检查作为一种可靠工具,用于涉及枕下深层肌肉的肌肉骨骼(MSK)疾病评估和管理中的临床及研究应用。设计与设置 对17名参与者进行了MSK超声检查评估,其中包括9名女性和8名无颈部或脊柱疼痛的男性。使用实时B型超声在坐位下评估枕下肌肉的可见CSA,在一张超声图像中,使用线性探头(5 cm,7.5 MHz)垂直于头后小直肌(RCPM)的肌纤维进行测量,在另一张超声图像中垂直于头下斜肌(OCI)和头后大直肌(RCPMJ)的肌纤维进行测量。两名经验丰富的检查者进行超声测量,该过程在一小时后和一天后重复进行。结果 检查者1在一小时和一天重复测量时,RCPM的组内相关系数(ICC)值分别为0.84和0.79,RCPMJ的ICC值分别为0.84和0.71,OCI的ICC值分别为0.86和0.77。检查者2在一小时和一天重复测量时,RCPM的ICC值分别为0.86和0.77,RCPMJ的ICC值分别为0.77和0.86,OCI的ICC值分别为0.61和0.64。不同检查者之间的ICC值,RCPM为0.77,RCPMJ为0.82,OCI为0.68。检查者1的测量标准误(SEM)值,RCPM为11.63和13.92 mm²,RCPMJ为10.30和7.91 mm²,OCI为22.84和34.61 mm²。检查者2的SEM值,RCPM为11.82和13.40 mm²,RCPMJ为11.91和7.04 mm²,OCI为39.20和37.73 mm²。检查者之间的SEM值,RCPM为13.74 mm²,RCPMJ为10.36 mm²,OCI为36.03 mm²。结论 这些发现表明,超声检查是一种可靠的方法,可用于测量RCPM、RCPMJ和OCI肌肉的CSA,前提是检查者训练有素且技术一致,并使用三次测量的平均值。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/fc3f/11456216/47a8bd42b4c7/cureus-0016-00000068772-i01.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验