Suppr超能文献

肩袖修复四种不同缝合构型的比较:一项生物力学动物研究。

Comparison between four different suture configurations for rotator cuff repair: a biomechanical animal study.

作者信息

Haroun Yahia, Sobhy Mohamed H, Khater Hany A, Khater Ahmad H

机构信息

Orthopedic Surgery, Faculty of Medicine, Ain Shams University, 38 Abbassia, next to the Al-Nour Mosque, 11566 Cairo, Egypt.

Orthopedic Surgery, Ain Shams University, 38 Abbassia, next to the Al-Nour Mosque, 11566 Cairo, Egypt.

出版信息

SICOT J. 2024;10:39. doi: 10.1051/sicotj/2024038. Epub 2024 Oct 7.

Abstract

INTRODUCTION

The arthroscopic repair of a massive rotator cuff tear could be surgically challenging. There is a continuous argument regarding the best surgical technique and suture configuration used to treat massive rotator cuff tears. The purpose of this study was to assess the in vitro strength of the new double Mason-Allen suture and compare it to the commonly used other suture configurations.

METHODS

Twenty-five fresh sheep shoulders were randomly divided into five equal groups. Each group had their infraspinatus tendons cut and repaired with one of five suture configurations (simple, horizontal mattress, Mason-Allen, modified Mason-Allen, and double Mason-Allen) using Arthrex 1.3 mm suture tape. The specimens were fixed to the test apparatus through their scapulae and hung with the repair tape to Sartorius precision balance with sequential load increments till failure. The load to failure was measured for each of the five suture configurations.

RESULTS

Study data found the double Mason-Allen configuration to have the highest mean load to failure 423.30 ± 23.05 (Newtons), followed by modified Mason-Allen, Mason-Allen, horizontal mattress, and simple suture respectively.

CONCLUSION

The double Mason-Allen repair configuration has the highest load to failure compared to the other known suture configuration to repair rotator cuff tears.

摘要

引言

巨大肩袖撕裂的关节镜修复手术具有挑战性。关于治疗巨大肩袖撕裂的最佳手术技术和缝线配置一直存在争议。本研究的目的是评估新型双梅森 - 艾伦缝线的体外强度,并将其与常用的其他缝线配置进行比较。

方法

将25个新鲜羊肩随机分为五组。每组的冈下肌腱被切断,并用Arthrex 1.3毫米缝线带以五种缝线配置(简单缝线、水平褥式缝线、梅森 - 艾伦缝线、改良梅森 - 艾伦缝线和双梅森 - 艾伦缝线)之一进行修复。标本通过肩胛骨固定在测试装置上,并用修复带悬挂在 Sartorius 精密天平上,依次增加负荷直至失效。测量五种缝线配置中每种配置的失效负荷。

结果

研究数据发现,双梅森 - 艾伦配置的平均失效负荷最高,为423.30 ± 23.05(牛顿),其次分别是改良梅森 - 艾伦缝线、梅森 - 艾伦缝线、水平褥式缝线和简单缝线。

结论

与其他已知的用于修复肩袖撕裂的缝线配置相比,双梅森 - 艾伦修复配置具有最高的失效负荷。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6c78/11458134/89dd55fc26f3/sicotj-10-39-fig1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验