Intra- and inter-rater reliability of goniometric finger range of motion using a written protocol.

作者信息

Nakai Takuya, Amano Satoru, Murao Chikako, Taguchi Haruki, Takahashi Kayoko

机构信息

Department of Occupational Therapy, Kitasato University Hospital, Kanagawa - Japan.

School of Allied Health Sciences, Kitasato University, Kanagawa - Japan.

出版信息

Arch Physiother. 2024 Oct 8;14:83-88. doi: 10.33393/aop.2024.3049. eCollection 2024 Jan-Dec.

Abstract

INTRODUCTION

Goniometric finger range of motion (ROM) is the most common outcome measure used for functional evaluation of finger joints, but its reliability is not well-evaluated. This study aimed to investigate intra- and inter-rater reliability of goniometric finger ROM using a written protocol for active, passive, and composite movements in healthy adults.

METHODS

The design was a single-center, cross-sectional, reliability study. Participants were 20 healthy adults (mean ± standard deviation, 36.4 ± 10.9 years). ROM for active, passive, and composite movements of the fingers was assessed by three occupational therapists with at least 5 years clinical experience in the field of physical disabilities. To standardize the measurement method used, we developed a written protocol, stabilized the wrist position, and trained the evaluators. Intraclass correlation coefficient (ICC) values were used for the reliability analysis. ICC (1,1) was used for intra-rater reliability. ICC (2,1) was used for inter-rater reliability. Hand-shaped heatmaps were used to summarize the reliability data.

RESULTS

Most of the results (88.7%) showed moderate to good intra-rater reliability (ICC ≥ 0.50), while inter-rater reliability showed less (69.0%). Both intra- and inter-rater reliability showed no trends between dominant and non-dominant hands, type of movement, finger, or joint.

CONCLUSIONS

Intra-rater reliability was relatively high and using a written protocol was beneficial. Inter-rater reliability tended to be lower, and differences in the physical structure of both raters and participants may have affected inter-rater reliability values.

摘要

引言

测角法测量的手指活动范围(ROM)是用于手指关节功能评估最常用的结果指标,但其可靠性尚未得到充分评估。本研究旨在通过一份针对健康成年人主动、被动和复合运动的书面方案,调查测角法测量手指ROM的评估者内和评估者间可靠性。

方法

本研究为单中心横断面可靠性研究。参与者为20名健康成年人(平均±标准差,36.4±10.9岁)。由三名在肢体残疾领域至少有5年临床经验的职业治疗师评估手指主动、被动和复合运动的ROM。为规范所使用的测量方法,我们制定了一份书面方案,稳定手腕位置,并对评估者进行培训。采用组内相关系数(ICC)值进行可靠性分析。ICC(1,1)用于评估者内可靠性分析。ICC(2,1)用于评估者间可靠性分析。使用手部热图总结可靠性数据。

结果

大多数结果(88.7%)显示评估者内可靠性为中度至良好(ICC≥0.50),而评估者间可靠性较低(69.0%)。评估者内和评估者间可靠性在优势手与非优势手、运动类型、手指或关节之间均无趋势差异。

结论

评估者内可靠性相对较高,使用书面方案有益。评估者间可靠性往往较低,评估者和参与者身体结构的差异可能影响了评估者间可靠性值。