He Jialing, Zhang Zhen, Yang Guoshu, Luo Duan, Xiong Shiqiang, Yang Yongxin, He Guijun, Liu Hanxiong
Department of Cardiology, The Affiliated Hospital of Southwest Jiaotong University, The Third People's Hospital of Chengdu, Cardiovascular Disease Research Institute of Chengdu, Chengdu, Sichuan 610031, P.R. China.
Exp Ther Med. 2024 Sep 27;28(6):442. doi: 10.3892/etm.2024.12731. eCollection 2024 Dec.
Pulsed field ablation (PFA), a nonthermal ablative mechanism, has been proven to be effective and safe in clinical application. To date, PFA has been used for only atrial fibrillation (AF) ablation in limited clinical trials. The present study describes a case of paroxysmal AF in which mitral and cavotricuspid isthmus (CTI)-dependent atrial flutter was discovered incidentally during PFA operation and successfully ablated with PFA. This is the first medical record of PFA for AF combined with mitral and CTI atrial flutter. The present case report revealed that PFA can be independently used to treat complex arrhythmias, similar to radiofrequency (RF) ablation, without the need for assistance from other ablation methods. Concurrently, the present study, to the best of the authors' knowledge is the first to report a case using a point-to-point PFA ablation strategy for isthmus ablation. This highlights the potential of PFA in treating diverse arrhythmias across different regions, such as the mitral isthmus and other intricate areas, utilizing a point-to-point PFA ablation strategy.
脉冲场消融(PFA)是一种非热消融机制,已被证明在临床应用中有效且安全。迄今为止,在有限的临床试验中,PFA仅用于心房颤动(AF)消融。本研究描述了一例阵发性AF病例,在PFA手术过程中偶然发现了二尖瓣和腔静脉三尖瓣峡部(CTI)依赖性心房扑动,并成功地用PFA进行了消融。这是PFA用于AF合并二尖瓣和CTI心房扑动的首例医学记录。本病例报告显示,PFA可独立用于治疗复杂心律失常,类似于射频(RF)消融,无需其他消融方法的辅助。同时,据作者所知,本研究首次报告了使用点对点PFA消融策略进行峡部消融的病例。这凸显了PFA利用点对点PFA消融策略治疗不同区域(如二尖瓣峡部和其他复杂区域)各种心律失常的潜力。