BACKGROUND

The arms of chairs in outpatient oncology clinics are frequently contaminated with cyclophosphamide.

OBJECTIVE

To evaluate the effectiveness of decontamination scenarios.

METHODS

This was a descriptive simulation-type study of 6 decontamination scenarios of a silicone fabric surface contaminated with 10 μg of cyclophosphamide. The decontamination products tested (quaternary ammonium, 0.5% hydrogen peroxide, 0.005% detergent, and sodium hypochlorite 0.5%) were applied with microfibre wipes. Residual contamination was measured using an ultra-performance liquid chromatography-tandem mass spectrometry system with identical cyclophosphamide detection and quantification limits (0.0006 ng/cm).

RESULTS

Among the 59 samples, 3 blanks were negative, 5 allowed measurement of the recovery rate (93.7% [standard deviation 4.6%]), and 51 were experimental. The average efficiency of the agents was greater than or equal to 99.79%. Regardless of the agent used, effectiveness was 99.30% (SD 1.20%) after 1 cleanse ( = 18), 99.90% (SD 0.15%) after 2 cleanses ( = 18), and 99.95% (SD 0.06%) after 3 cleanses ( = 15).

CONCLUSION

The 6 decontamination scenarios were effective. Repeated cleaning marginally increased the effectiveness of decontamination.

摘要

背景

肿瘤门诊诊所椅子的扶手经常被环磷酰胺污染。

目的

评估去污方案的有效性。

方法

这是一项描述性模拟研究,针对被10μg环磷酰胺污染的硅酮织物表面进行6种去污方案的研究。测试的去污产品(季铵盐、0.5%过氧化氢、0.005%洗涤剂和0.5%次氯酸钠)用微纤维擦拭布进行涂抹。使用具有相同环磷酰胺检测和定量限(0.0006 ng/cm)的超高效液相色谱-串联质谱系统测量残留污染。

结果

在59个样本中,3个空白样本为阴性,5个样本可测量回收率(93.7%[标准差4.6%]),51个样本为实验样本。这些试剂的平均效率大于或等于99.79%。无论使用何种试剂,一次清洁后有效性为99.30%(标准差1.20%)(n = 18),两次清洁后为99.90%(标准差0.15%)(n = 18),三次清洁后为99.95%(标准差0.06%)(n = 15)。

结论

这6种去污方案是有效的。反复清洁可使去污效果略有提高。

相似文献

1
[Not Available].[无可用内容]
Can J Hosp Pharm. 2024 Oct 9;77(4):e3588. doi: 10.4212/cjhp.3588. eCollection 2024.
4
Evaluation of decontamination strategies for cyclophosphamide.环磷酰胺去污策略的评估
J Oncol Pharm Pract. 2020 Mar;26(2):413-422. doi: 10.1177/1078155219865931. Epub 2019 Aug 1.

本文引用的文献

2
Safe handling of hazardous drugs.危险药物安全处理。
J Oncol Pharm Pract. 2023 Mar;29(2):401-412. doi: 10.1177/10781552221135121. Epub 2022 Nov 13.
5
Evaluation of decontamination strategies for cyclophosphamide.环磷酰胺去污策略的评估
J Oncol Pharm Pract. 2020 Mar;26(2):413-422. doi: 10.1177/1078155219865931. Epub 2019 Aug 1.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验