This study investigated whether there are differences between software programs, voxel sizes, segmentation techniques, and intraoral scanners in terms of volume measurement in incisor teeth.
Thirty extracted teeth were scanned using a 3D intraoral scanner. Physical volumes were measured using the water displacement method (WDM) as the gold standard. Cone beam computed tomography images were taken at two voxel sizes (0.3-0.4 mm voxel). The volumes of the teeth were calculated using the manual segmentation technique in the 3D Doctor and ImageJ (Fiji) Program, manual and automatic segmentation methods in the ITK-Snap program, and automatic segmentation methods in the 3D Slicer program. The data were analyzed using the Statistical Package for Social Sciences (SPSS, v 20.0).
There is a significant difference between WDM and 3D Doctor volume measurements at the voxel size of 0.4 mm (P < .05). The 3D Doctor program showed more than 13% difference compared to the WDM. There is no significant difference between WDM, intraoral scanner, ITK-Snap, ImageJ (Fiji), 3D Slicer, and 3D-Doctor volume measurements at the voxel size of 0.3 mm.
Measurements with manual segmentation in ITK-Snap and ImageJ programs give the closest results to the physical volume measurements of the teeth. The automatic segmentation method in ITK-Snap and 3D Slicer programs may be preferred due to its ease of use and less time-consuming. In the 3D Doctor software, volume measurements tend to increase with larger voxel size.
本研究旨在探讨在切牙的体积测量方面,软件程序、体素大小、分割技术和口内扫描仪之间是否存在差异。
将 30 颗离体牙使用 3D 口内扫描仪进行扫描。使用水置换法(WDM)作为金标准测量物理体积。在两种体素大小(0.3-0.4mm 体素)下获取锥形束 CT 图像。使用 3D Doctor 和 ImageJ(Fiji)程序中的手动分割技术、ITK-Snap 程序中的手动和自动分割方法以及 3D Slicer 程序中的自动分割方法计算牙齿的体积。使用社会科学统计软件包(SPSS,v 20.0)对数据进行分析。
在体素大小为 0.4mm 时,WDM 和 3D Doctor 体积测量之间存在显著差异(P<.05)。3D Doctor 程序与 WDM 相比,差异超过 13%。在体素大小为 0.3mm 时,WDM、口内扫描仪、ITK-Snap、ImageJ(Fiji)、3D Slicer 和 3D Doctor 体积测量之间无显著差异。
ITK-Snap 和 ImageJ 程序中的手动分割测量结果与牙齿的物理体积测量最接近。由于其易于使用和耗时较少,ITK-Snap 和 3D Slicer 程序中的自动分割方法可能更受欢迎。在 3D Doctor 软件中,随着体素大小的增加,体积测量值趋于增加。