McCool F D, Leith D E
J Appl Physiol (1985). 1986 Jan;60(1):304-6. doi: 10.1152/jappl.1986.60.1.304.
The relationship between mean values of pressure (pressure-time integral including both inspiration and expiration) measured at the airway opening (Pao) and in the esophagus (Pes) is described for ventilation on a variety of external inspiratory resistances. Pao/Pes was 0.85 or greater when the external inspiratory resistance was a 4.0-mm or smaller endotracheal tube adaptor. Additionally, Pao can be easily and accurately measured by a slowly responding mechanical manometer. This device is simple in design, unpowered, inexpensive, and can be used outside the laboratory as part of an inspiratory muscle training program.