Suppr超能文献

用于类风湿性关节炎的掌指关节硅胶橡胶植入关节成形术。

Silicone-rubber implant arthroplasty of the metacarpophalangeal joints for rheumatoid arthritis.

作者信息

Bieber E J, Weiland A J, Volenec-Dowling S

出版信息

J Bone Joint Surg Am. 1986 Feb;68(2):206-9.

PMID:3944159
Abstract

Forty-six patients with rheumatoid arthritis underwent metacarpophalangeal-joint arthroplasty of the index through little fingers on 210 joints in fifty-five hands using the Swanson-design silicone-rubber spacer. The patients were followed for two to eight years (average, five and one-quarter years). They were evaluated both preoperatively and postoperatively for range of motion, deformity, subjective sense, grip strength, and prehension. In the initial postoperative evaluation, the majority of patients expressed a strong subjective impression of improvement. Ulnar drift improved from the preoperative average of 25 degrees to less than 5 degrees. The preoperative average extension deficit decreased from 56 to 10 degrees, while the average range of motion increased from 17 to 51 degrees. In the long-term postoperative evaluation, the average ulnar drift had increased to 12 degrees, the average extension deficit had increased to 22 degrees, and the average range of motion had decreased to 39 degrees. Grip strength and prehension did not significantly improve at either evaluation. There were no fractures of the prosthesis and no patient had synovitis. We have found the procedure to be useful for the correction of deformity, increasing range of motion of the fingers, and improving the patient's sense of well-being.

摘要

46例类风湿性关节炎患者使用斯旺森设计的硅橡胶间隔器对55只手的210个关节进行了示指至小指的掌指关节置换术。对患者进行了2至8年(平均5年零3个月)的随访。术前和术后均对患者的活动范围、畸形、主观感受、握力和抓握能力进行了评估。在术后初期评估中,大多数患者表示主观感觉有明显改善。尺偏从术前平均25度改善至小于5度。术前平均伸展受限从56度降至10度,而平均活动范围从17度增加至51度。在术后长期评估中,平均尺偏增加至12度,平均伸展受限增加至22度,平均活动范围降至39度。两次评估中握力和抓握能力均未显著改善。假体未发生骨折,也没有患者出现滑膜炎。我们发现该手术对于纠正畸形、增加手指活动范围以及改善患者的幸福感很有用。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验