Suppr超能文献

[类风湿关节炎中第二至第五掌指关节的硅橡胶植入关节成形术]

[Silastic implant arthroplasty of the second to fifth metacarpophalangeal joints in rheumatoid arthritis].

作者信息

Dobiás J, Pech J, Popelka S

机构信息

I.ortopedická klinika 1. LF UK a FN Motol, Praha.

出版信息

Acta Chir Orthop Traumatol Cech. 2007 Aug;74(4):278-86.

Abstract

PURPOSE OF THE STUDY

The authors evaluate the long-term results of metacarpophalangeal joint (MCP) arthroplasty of the second to fifth digits in the rheumatoid hand in relation to the factors that have a long-term effect on implant function.

MATERIAL

In a group of 41 patients, 52 hands were treated with a total of 166 Swanson silastic MCP implants in the period from 1988 to 2005. The average follow-up was 3.2 years (range, 6 months to 17 years). Arthroplasty was carried out exclusively for the indication of rheumatoid destruction of MCP joints.

METHODS

The patients were assessed for the range of motion, MCP joint alignment and functional and radiographic findings. Xray images were examined for osseous lesions at the margins of resected parts, implant position and its state and joint alignment. Radiography was performed from the standard distance in anteroposterior and oblique projections. Subjective satisfaction of the patients was evaluated on the basis of a questionnaire, in which hand function, pain and cosmetic appearance were recorded.

RESULTS

The function and mobility of the fingers improved after surgery, with an increased range of motion in MCP joints towards extension (average range, 3 degrees to 51 degrees flexion), and correction of an ulnar drift of the MCP joint of each finger (average, 5.8 degrees ). Radiographs showed destruction of silastic implants in 13.3 % of the fingers treated. The subjective evaluation by patients was satisfactory. Long-lasting pain relief was reported by 79 % and satisfaction with hand function by 90 % of the patients. Improvement in a cosmetic appearance of the hand was also significant.

DISCUSSION

At long-term follow-up, a gradual decrease in the range of motion of MCP joints and a partial recurrence of ulnar drift usually occur at about 2 years. However, in most cases, they do not result in either subjective complaints or functional restriction. These findings are in agreement with the results published in the relevant literature.

CONCLUSIONS

The silastic implant remains a standard procedure in surgical reconstruction of the MCP joints in the rheumatoid hand. Improvements in the range of motion and joint alignment and alleviation of pain result in a markedly improved hand function and patients' satisfaction. The long-term outcome of MCP joint arthroplasty is significantly influenced by the severity of rheumatoid arthritis.

摘要

研究目的

作者评估类风湿性手部第二至五指掌指关节(MCP)置换术的长期结果,并探讨对植入物功能产生长期影响的因素。

材料

1988年至2005年期间,对41例患者的52只手进行了治疗,共植入166枚斯旺森硅橡胶MCP植入物。平均随访时间为3.2年(范围为6个月至17年)。关节置换术仅用于治疗类风湿性MCP关节破坏。

方法

对患者的活动范围、MCP关节对线情况以及功能和影像学检查结果进行评估。对X线图像检查切除部位边缘的骨质病变、植入物位置及其状态以及关节对线情况。在前后位和斜位投影的标准距离下进行X线摄影。根据问卷评估患者的主观满意度,记录手部功能、疼痛和外观情况。

结果

术后手指的功能和活动度得到改善,MCP关节向伸展方向的活动范围增加(平均范围为3度至51度屈曲),每个手指的MCP关节尺偏得到纠正(平均为5.8度)。X线片显示,在接受治疗的手指中,13.3%的硅橡胶植入物出现破坏。患者的主观评价为满意。79%的患者报告疼痛得到长期缓解,90%的患者对手部功能满意。手部外观也有显著改善。

讨论

在长期随访中,MCP关节的活动范围通常在大约2年时逐渐减小,尺偏部分复发。然而,在大多数情况下,这些情况不会导致主观不适或功能受限。这些结果与相关文献发表的结果一致。

结论

硅橡胶植入物仍然是类风湿性手部MCP关节手术重建的标准方法。活动范围和关节对线的改善以及疼痛的减轻显著改善了手部功能和患者满意度。MCP关节置换术的长期结果受类风湿性关节炎严重程度的显著影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验