Shanghai Anti-Doping Laboratory, Shanghai University of Sport, Shanghai, 200438, China.
Anal Bioanal Chem. 2024 Dec;416(29):7073-7084. doi: 10.1007/s00216-024-05612-2. Epub 2024 Oct 25.
Given the critical nature of anti-doping efforts, the detection of stimulant substances is shifting from accurate qualitative analysis to precise quantitative analysis. Additionally, the use of liquid chromatography-high-resolution mass spectrometry (LC-HRMS) in detecting stimulants is becoming more widespread. However, the lack of isotope-labeled internal standards is causing increasing issues with quantitative accuracy. Furthermore, challenges such as the mass spectrometric response of small molecules and the separation of isomers present additional difficulties. We have developed a quantitative method for stimulant substances containing amine or phenol hydroxyl groups, using a dual-label derivatization system. This method offers a new perspective for analyzing and detecting low molecular weight substances, isomers, or those with poor LC-MS response, and proposes a solution to the problem of missing isotope-labeled internal standards. Methodological validation has shown that this approach has promising application potential.
鉴于反兴奋剂工作的重要性,兴奋剂物质的检测正从准确的定性分析转向精确的定量分析。此外,液相色谱-高分辨质谱(LC-HRMS)在兴奋剂检测中的应用也越来越广泛。然而,缺乏同位素标记的内标物导致定量准确性的问题日益突出。此外,小分子的质谱响应以及异构体的分离等挑战也带来了更多的困难。我们开发了一种针对含有胺基或酚羟基的兴奋剂物质的定量方法,使用双重标记衍生化系统。该方法为分析和检测低分子量物质、异构体或 LC-MS 响应较差的物质提供了新的视角,并为解决同位素标记内标物缺失的问题提供了一种解决方案。方法学验证表明,该方法具有广阔的应用前景。