Suppr超能文献

单次力量评估过程中手持测力计的重测信度。

Test-retest reliability of hand-held dynamometry during a single session of strength assessment.

作者信息

Bohannon R W

出版信息

Phys Ther. 1986 Feb;66(2):206-9. doi: 10.1093/ptj/66.2.206.

Abstract

This retrospective study was undertaken to determine the test-retest reliability of hand-held dynamometer strength testing for 18 extremity muscle groups. To assess reliability, I compared three dynamometer strength scores recorded for each muscle group on the strength score forms of 30 neurologically involved patients, using the Pearson product-moment correlation and a one-way analysis of variance (ANOVA) for repeated measures. All correlations were significant (p less than .01); the median and modal correlations were all .97 or .98. The ANOVA revealed significant differences in repeated dynamometer test scores only for hip and shoulder abduction. The results suggest that hand-held dynamometry can be a reliable assessment technique when practiced by a single experienced tester.

摘要

本回顾性研究旨在确定针对18个肢体肌肉群的手持测力计力量测试的重测信度。为评估信度,我比较了30例神经受累患者力量评分表上每个肌肉群记录的三个测力计力量评分,采用Pearson积差相关和重复测量的单因素方差分析(ANOVA)。所有相关性均具有显著性(p小于0.01);中位数和众数相关性均为0.97或0.98。方差分析显示,仅在髋关节和肩关节外展的重复测力计测试评分中有显著差异。结果表明,当由一名经验丰富的测试者进行操作时,手持测力计测量法可以成为一种可靠的评估技术。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验