Suppr超能文献

用于图形视觉诱发电位测试的改良分析方案。

A modified analysis protocol for the PhNR test.

作者信息

Ridder William H, Farmer Jeffrey D

机构信息

Southern California College of Optometry, Marshall B. Ketchum University, 2575 Yorba Linda Blvd, Fullerton, CA, 92831, USA.

Diagnosys LLC, 55 Technology Dr #100, Lowell, MA, 01851, USA.

出版信息

Doc Ophthalmol. 2024 Dec;149(3):151-163. doi: 10.1007/s10633-024-09995-6. Epub 2024 Oct 30.

Abstract

PURPOSE

Several studies have reported that glaucoma patients have abnormal photopic negative response (PhNR) results compared to reference control subjects. The International Society for Clinical Electrophysiology of Vision (ISCEV) released an extended protocol for PhNR (I-PhNR) in 2018. The purpose of this study was to compare the I-PhNR protocol to a similar protocol modified (M-PhNR) to enhance the performance of the method in detecting glaucomatous damage.

METHODS

Thirty subjects were enrolled in this study (12 glaucoma patients, 10 glaucoma suspects, 8 normal controls). PhNR tests were conducted with a Diagnosys E3 mobile system (Diagnosys LLC, Lowell, MA). I-PhNR tests utilized all parameters specified by the ISCEV requirement. M-PhNR tests used the same parameters as the ISCEV tests with the exceptions of a 5-45 Hz bandpass filter and a novel, objective sweep-selection parameter. According to the ISCEV protocol, the PhNR relative to baseline (i.e., BT), a-wave and b-wave response amplitudes and BT/b-wave amplitude ratios were measured. Coefficients of variation, receiver operating characteristic (ROC) curves, and t-tests were used to assess the data from one randomly chosen eye per subject.

RESULTS

The M-PhNR protocol resulted in a decrease in the intra-subject repeat test coefficient of variation and a decrease in the average inter-subject coefficient of variation for the glaucoma subjects. The ROC curves demonstrated an increase in the area under the curve (AUC) for the M-PhNR compared to the I-PhNR protocol. The sensitivity and specificity were also greater for the M-PhNR protocol.

CONCLUSIONS

The M-PhNR protocol resulted in a decrease in intra-subject and inter-subject data variability which resulted in a significant increase in the ROC AUC, sensitivity, and specificity for glaucoma. Thus, the M-PhNR protocol shows promise as a better diagnostic tool than the I-PhNR protocol for detecting glaucoma.

摘要

目的

多项研究报告称,与正常对照受试者相比,青光眼患者的明视负反应(PhNR)结果异常。国际视觉临床电生理学会(ISCEV)于2018年发布了PhNR扩展方案(I-PhNR)。本研究的目的是将I-PhNR方案与改良的类似方案(M-PhNR)进行比较,以提高该方法在检测青光眼性损伤方面的性能。

方法

本研究纳入了30名受试者(12名青光眼患者、10名青光眼疑似患者、8名正常对照者)。使用Diagnosys E3移动系统(Diagnosys LLC,马萨诸塞州洛厄尔)进行PhNR测试。I-PhNR测试采用了ISCEV要求指定的所有参数。M-PhNR测试使用与ISCEV测试相同的参数,但有5-45Hz带通滤波器和一个新颖的客观扫描选择参数除外。根据ISCEV方案,测量相对于基线(即BT)的PhNR、a波和b波反应振幅以及BT/b波振幅比。变异系数、受试者工作特征(ROC)曲线和t检验用于评估每个受试者一只随机选择眼睛的数据。

结果

M-PhNR方案使青光眼受试者的受试者内重复测试变异系数降低,受试者间平均变异系数降低。ROC曲线显示,与I-PhNR方案相比,M-PhNR的曲线下面积(AUC)增加。M-PhNR方案的敏感性和特异性也更高。

结论

M-PhNR方案降低了受试者内和受试者间的数据变异性,从而导致青光眼的ROC AUC、敏感性和特异性显著增加。因此,与I-PhNR方案相比,M-PhNR方案有望成为检测青光眼的更好诊断工具。