Wang Hui, Lei Tze-Huan, Schlader Zachary J, Mündel Toby, Amano Tatsuro, Fujii Naoto, Nishiyasu Takeshi, Kondo Narihiko
Laboratory for Applied Human Physiology, Graduate School of Human Development and Environment, Kobe University, Kobe, Japan.
College of Physical Education, Hubei Normal University, Huangshi, China.
J Therm Biol. 2023 Oct 13;118:103724. doi: 10.1016/j.jtherbio.2023.103724.
This study investigated the efficacy of voluntary fan utilization on autonomic thermoeffector responses and thermal perceptions during passive heating by lower leg immersion (42 °C) in a 27 °C ambient temperature, 50% relative humidity. Fourteen young healthy adults (8 females) were recruited for this study where they underwent two trials with (Fan) and without an electric fan (No fan) during 50 min of passive heat stress. The skin temperature on forearm and abdomen was lower in Fan than in No fan (all p < 0.02), and the local skin temperature on the chest, and mean skin temperature were significantly lower in Fan than in No fan in the final 20 min (mean value of mean skin temperature: 34.77(0.15) °C vs 35.11(0.12) °C, respectively, all p < 0.03), whilst the rectal temperature was not different between trials (37.11(0.23) °C vs 37.08(0.27) °C, p = 0.78). The sensitivity of local sweat rate (LSR) with the increase of mean body temperature on the chest and forearm was significantly lower in Fan than No fan trials (all p < 0.02). The sum value of thermal sensation was lower and wetness was higher in Fan than in No fan in the final 25 min (thermal sensation: 7.50 (1.25) vs 5.00 (3.06), wetness: -6.57 (2.31) vs -5.21 (2.46), all p<0.03) whilst thermal discomfort did not differ significantly between trials (p = 0.12). The voluntary use of an electric fan attenuates the autonomic thermoeffector response, such as sweating, and influences thermal sensation and wetness but did not affect core temperature and thermal discomfort during lower leg immersion.
本研究调查了在环境温度27°C、相对湿度50%的条件下,通过小腿浸入(42°C)进行被动加热时,自主使用风扇对自主热效应器反应和热感觉的影响。招募了14名年轻健康成年人(8名女性)参与本研究,他们在50分钟的被动热应激期间分别进行了两次试验,一次使用风扇(Fan),一次不使用电风扇(No fan)。风扇组前臂和腹部的皮肤温度低于无风扇组(所有p<0.02),在最后20分钟,风扇组胸部的局部皮肤温度和平均皮肤温度显著低于无风扇组(平均皮肤温度的平均值:分别为34.77(0.15)°C和35.11(0.12)°C,所有p<0.03),而两次试验之间直肠温度没有差异(37.11(0.23)°C对37.08(0.27)°C,p = 0.78)。与无风扇试验相比,风扇组胸部和前臂平均体温升高时局部出汗率(LSR)的敏感性显著降低(所有p<0.02)。在最后25分钟,风扇组的热感觉总和值较低,湿度较高(热感觉:7.50(1.25)对5.00(3.06),湿度:-6.57(2.31)对-5.21(2.46),所有p<0.03),而两次试验之间的热不适没有显著差异(p = 0.12)。自主使用电风扇可减弱自主热效应器反应,如出汗,并影响热感觉和湿度,但在小腿浸入过程中不影响核心体温和热不适。