Gwirtz P A
J Appl Physiol (1985). 1986 Feb;60(2):720-6. doi: 10.1152/jappl.1986.60.2.720.
Construction of a Silastic catheter and the procedure for chronic implantation in a coronary artery in dogs is described. In addition, studies designed to evaluate whether chronic coronary artery catheterization altered coronary vascular reactivity and myocardial function are presented. The results of these studies indicate that chronic implantation of the catheter in a coronary artery of conscious dogs does not significantly interfere with the normal reactivity of the coronary vascular bed, does not compromise regional or global left ventricular function, and does not induce collateral vessel development. This technique will be useful in studies involving the neural and metabolic regulation of the coronary circulation in animals subjected to exercise and/or exercise training.
本文描述了一种硅橡胶导管的构造以及在犬冠状动脉中进行慢性植入的程序。此外,还介绍了旨在评估慢性冠状动脉插管是否会改变冠状动脉血管反应性和心肌功能的研究。这些研究结果表明,在清醒犬的冠状动脉中慢性植入导管不会显著干扰冠状动脉血管床的正常反应性,不会损害局部或整体左心室功能,也不会诱导侧支血管形成。该技术将有助于涉及运动和/或运动训练动物冠状动脉循环神经和代谢调节的研究。