Xiao Yi, Gabra Mari Ishak, Leung Edward
Department of Pathology and Laboratory Medicine, Children's Hospital Los Angeles, Los Angeles, CA, USA.
Department of Pathology, University of Southern California Keck School of Medicine, Los Angeles, CA, USA.
J Mass Spectrom Adv Clin Lab. 2024 Oct 9;34:28-33. doi: 10.1016/j.jmsacl.2024.10.002. eCollection 2024 Nov.
Tacrolimus and cyclosporine are common immunosuppressants utilized post-organ transplantation to manage allograft rejection. Both have narrow therapeutic indices and are frequently measured to support dose adjustments. Although nasogastric tubes are commonly used to provide nutritional support and serve as a route for immunosuppressant administration, they were never validated for such purposes.
To develop and validate a liquid chromatography - tandem mass spectrometry (LC-MS/MS) method for highly concentrated tacrolimus and cyclosporine samples prepared from pharmaceutical products to support the validation of feeding tube administration of these immunosuppressants.
The method involved stepwise dilutions with dimethyl sulfoxide before analysis using online sample preparation and LC-MS/MS. It was validated in a CLIA-certified clinical laboratory that measures immunosuppressants by LC-MS/MS and is designed to support clinical studies evaluating drug loss from feeding tubes.
The method was linear between 6.8 µg/mL and 75 µg/mL for tacrolimus, and between 0.9 mg/mL and 10 mg/mL for cyclosporine, with r > 0.99 and total precision <5 % at all QC levels. The method demonstrated good recovery using cyclosporine Certified Reference Material, tacrolimus European Pharmacopeia Reference Standard, and prepared pharmaceutical products. Minimal matrix effects were observed.
An analytical method was developed and validated for studies with simulated administration of tacrolimus or cyclosporine to assess loss during drug administration using feeding tubes.
他克莫司和环孢素是器官移植后常用的免疫抑制剂,用于处理移植器官排斥反应。两者的治疗指数都很窄,因此经常进行测量以支持剂量调整。尽管鼻胃管常用于提供营养支持并作为免疫抑制剂给药途径,但从未针对此类用途进行过验证。
开发并验证一种液相色谱-串联质谱(LC-MS/MS)方法,用于分析从药品制备的高浓度他克莫司和环孢素样品,以支持这些免疫抑制剂经饲管给药的验证。
该方法包括在分析前用二甲基亚砜进行逐步稀释,采用在线样品制备和LC-MS/MS。该方法在一家通过CLIA认证的临床实验室中得到验证,该实验室采用LC-MS/MS测量免疫抑制剂,旨在支持评估饲管药物损失的临床研究。
该方法对他克莫司在6.8μg/mL至75μg/mL之间呈线性,对环孢素在0.9mg/mL至10mg/mL之间呈线性,所有质量控制水平下r>0.99,总精密度<5%。使用环孢素标准物质、他克莫司欧洲药典标准品和制备的药品,该方法显示出良好的回收率。观察到最小的基质效应。
开发并验证了一种分析方法,用于他克莫司或环孢素模拟给药研究,以评估经饲管给药期间的药物损失。