Suppr超能文献

icobrain在多发性硬化症临床实践中用于脑容量测定的效用。

Utility of icobrain for brain volumetry in multiple sclerosis clinical practice.

作者信息

Nguyen Ai-Lan, Sormani Maria Pia, Horakova Dana, Havrdova Eva H, Barnett Michael H, De Stefano Nicola, Battaglini Marco, Vaneckova Manuela, Lui Elaine, Gaillard Frank, Desmond Patricia M, Prime Hayden, Datta Mineesh, Van der Walt Anneke, Jokubaitis Vilija G, Podevyn Femke, Zivadinov Robert, Weinstock-Guttman Bianca, D'hooghe Marie B, Nagels Guy, Van Pesch Vincent, Laureys Guy, Van Hijfte Liesbeth, Lechner-Scott Jeannette, Patti Francesco, Cristiano Edgardo, Rojas Juan I, Sima Diana M, Van Hecke Wim, Kalincik Tomas, Butzkueven Helmut

机构信息

Neuroimmunology Centre, Royal Melbourne Hospital, University of Melbourne, Melbourne, Australia; CORe, Department of Medicine, University of Melbourne, Melbourne, Australia.

Department of Health Sciences (DISSAL), Biostatistics Unit, University of Genoa, Genoa, Italy.

出版信息

Mult Scler Relat Disord. 2024 Dec;92:106148. doi: 10.1016/j.msard.2024.106148. Epub 2024 Nov 8.

Abstract

BACKGROUND

Few studies on multiple sclerosis (MS) have explored the variability of percentage brain volume change (PBVC) measurements obtained from different clinical MRIs. In a retrospective multicentre cohort study, we quantified the variability of annualised PBVC in clinical MRIs.

METHODS

Clinical MRIs of relapse-onset MS patients were assessed by icobrain. Volumetric data were analysed on same-scanner and different-scanner MRI pairs if they passed quality control criteria. Alignment similarity between two images had to be comparable to same-scanner scan-rescan images.

RESULTS

Of 6826 MRIs, 85 % had appropriate volumetric sequences and 4446 serial MRI pairs were analysed. 3334 (75 %) MRI pairs from 1207 patients met the inclusions. The PBVC of included MRI pairs showed variance of 0.78 % for same-scanner pairs and 0.80 % for different-scanner pairs. Further selection of included MRI pairs with the best variance resulted in 1885 (42 %) MRI pairs with PBVC variance of 0.34 %. Excluded MRI pairs with poor alignment similarity had variances of 2.97 % for same-scanner pairs and 20.79 % for different-scanner pairs.

CONCLUSION

Icobrain should be utilised for PBVC determination only on selected MRIs with the best alignment similarity. Applying strict selection criteria for the included MRI pairs and longitudinal imaging on the same scanner remain mandatory to reduce PBVC variability.

摘要

背景

关于多发性硬化症(MS)的研究中,很少有探讨从不同临床磁共振成像(MRI)获得的脑体积变化百分比(PBVC)测量值的变异性。在一项回顾性多中心队列研究中,我们对临床MRI中PBVC的年度变异性进行了量化。

方法

复发型MS患者的临床MRI由icobrain评估。如果通过质量控制标准,则对同一扫描仪和不同扫描仪的MRI图像对进行体积数据分析。两张图像之间的对齐相似度必须与同一扫描仪的扫描-重扫图像相当。

结果

在6826例MRI中,85%具有合适的体积序列,共分析了4446对序列MRI。来自1207例患者的3334对(75%)MRI符合纳入标准。纳入的MRI对的PBVC显示,同一扫描仪对的方差为0.78%,不同扫描仪对的方差为0.80%。进一步选择方差最小的纳入MRI对,得到1885对(42%)PBVC方差为0.34%的MRI对。对齐相似度差的排除MRI对,同一扫描仪对的方差为2.97%,不同扫描仪对的方差为20.79%。

结论

仅应在对齐相似度最佳的选定MRI上使用icobrain进行PBVC测定。对纳入的MRI对应用严格的选择标准并在同一扫描仪上进行纵向成像,对于降低PBVC变异性仍然是必要的。