Suppr超能文献

在犬类模型中评估椎弓根螺钉-棒植入作为胫骨截骨外固定方法的效果。

Assessment of Pedicle screw-Rod implantation as an external fixation method for tibial osteotomy in a canine model.

作者信息

Gooran Mohammad Mahdi, Mazaheri-Khameneh Ramin, Hashemi-Asl Seyed Mohammad, Hobbenaghi Rahim

机构信息

Department of Surgery and Diagnostic Imaging, Faculty of Veterinary Medicine, Urmia University, Urmia, Iran.

Department of Pathobiology, Faculty of Veterinary Medicine, Urmia University, Urmia, Iran.

出版信息

Vet Anim Sci. 2024 Oct 30;26:100403. doi: 10.1016/j.vas.2024.100403. eCollection 2024 Dec.

Abstract

Recent advancements in minimally invasive osteosynthesis have improved atraumatic techniques for bone fracture fixation. Pedicle screws are implants primarily used for the internal fixation of the spine. To our knowledge, no studies have assessed the use of Pedicle screw-Rod for fixing long bone fractures or osteotomies. Our study aimed to assess the efficiency and performance of this implant as an external fixation method for experimentally induced tibial fractures, offering a novel surgical approach to tibial fixation. With approval from the Institutional Animal Care Committee, eight healthy, intact male dogs weighing 20-22 kg and aged 10-12 months of mixed breeds underwent aseptic surgical fixation of tibial osteotomies with Pedicle screw-Rod configuration using a minimally invasive medial approach to the tibia. All dogs were placed in the single treatment group. Postoperative clinical and radiographic evaluations were performed. The fixation device functioned effectively until removal. Lameness was fully resolved in all animals by 21 days post-operation. Clinical union occurred at 5.80 ± 1.30 weeks, while complete bone union was achieved at 11.40 ± 1.51 weeks after surgery. Postoperative mechanical medial proximal and distal tibial angles were, 92.00° (92.00°, 91.50°) and 93.40° ± 1.14°, respectively. The tibial valgus was 5.20° ± 1.48°, and tibial plateau angles measured 22.00° (23.00°, 22.00°). There were no significant differences noted when comparing values before and after the operation. Postoperative rotational alignment was anatomical, with satisfactory bone apposition. The study found that using a Pedicle Screw-Rod configuration for non-articular tibial osteotomy fixation is effective without significant complications.

摘要

微创骨合成技术的最新进展改进了骨折固定的无创技术。椎弓根螺钉是主要用于脊柱内固定的植入物。据我们所知,尚无研究评估椎弓根螺钉-棒用于固定长骨骨折或截骨术的情况。我们的研究旨在评估这种植入物作为实验性诱导胫骨骨折的外固定方法的效率和性能,为胫骨固定提供一种新颖的手术方法。经机构动物护理委员会批准,八只体重20-22千克、年龄10-12个月的健康完整杂种雄性犬接受了使用微创内侧入路至胫骨的椎弓根螺钉-棒构型对胫骨截骨术进行无菌手术固定。所有犬均置于单一治疗组。进行了术后临床和影像学评估。固定装置在取出前功能有效。所有动物在术后21天跛行完全消失。临床愈合发生在术后5.80±1.30周,而完全骨愈合在术后11.40±1.51周实现。术后胫骨近端和远端内侧机械角度分别为92.00°(92.00°,91.50°)和93.40°±1.14°。胫骨外翻为5.20°±1.48°,胫骨平台角度测量为22.00°(23.00°,22.00°)。比较手术前后的值时未发现显著差异。术后旋转对线呈解剖学状态且骨对位满意。该研究发现,使用椎弓根螺钉-棒构型进行非关节胫骨截骨术固定是有效的,且无明显并发症。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c30f/11570856/7a9014bdf8a7/ga1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验