To compare the intersubject reliability of cortical auditory evoked potential (CAEP) elicited by acoustic and electrical stimulations in pediatric cochlear implant (CI) recipients.
Twenty-two MED-EL CI recipients (aged 13-93 months) participated in this study. The acoustic CAEP (aCAEP) waveforms were elicited using four speech stimuli (/ba/, /m/, /g/, and /t/) presented at 65 dB SPL in a free-field condition. The electrical CAEP (eCAEP) responses were obtained by presenting electrical pulses through apical, medial, and basal electrodes. The aCAEP and eCAEP data (n = 28 ears) were analyzed using coefficient of variation (CV) and other appropriate statistics.
P1, N1, and P2 peaks were observed in most of the children (92.9% response rate). The CV values were smaller for the latency metric (13.6-34.2%) relative to the amplitude metric (51.3-92.4%), and the differences were statistically significant (p < 0.001). The aCAEP yielded smaller mean CV values than the eCAEP (for both latency and amplitude measures), and the mean CV value for the aCAEP (15.6%) was found to be statistically different from that of the eCAEP (31.0%) for the P1 latency (p = 0.001).
This study is the first to report the intersubject reliability of aCAEP and eCAEP in pediatric CI recipients. Overall, CAEP latencies were found to be more reliable than CAEP amplitudes, and the aCAEP testing demonstrated higher intersubject reliability compared to the eCAEP assessment. The present study's findings can be beneficial for researchers and clinicians in documenting CAEP in children who use CI.
比较小儿人工耳蜗(CI)植入受者中,声学和电刺激诱发的皮质听觉诱发电位(CAEP)的受试者间可靠性。
22名MED-EL CI植入受者(年龄13 - 93个月)参与了本研究。声学CAEP(aCAEP)波形通过在自由声场条件下以65 dB SPL呈现的四种语音刺激(/ba/、/m/、/g/和/t/)诱发。电CAEP(eCAEP)反应通过经顶、中、基底电极施加电脉冲获得。使用变异系数(CV)和其他适当的统计方法分析aCAEP和eCAEP数据(n = 28耳)。
大多数儿童(反应率92.9%)观察到P1、N1和P2波峰。潜伏期指标的CV值(13.6 - 34.2%)相对于幅度指标(51.3 - 92.4%)更小,差异具有统计学意义(p < 0.001)。aCAEP产生的平均CV值比eCAEP小(潜伏期和幅度测量均如此),并且发现aCAEP的P1潜伏期平均CV值(15.6%)与eCAEP的(31.0%)在统计学上不同(p = 0.001)。
本研究首次报告了小儿CI植入受者中aCAEP和eCAEP的受试者间可靠性。总体而言,发现CAEP潜伏期比CAEP幅度更可靠,并且与eCAEP评估相比,aCAEP测试显示出更高的受试者间可靠性。本研究结果对研究人员和临床医生记录使用CI的儿童的CAEP可能有益。