空气传导和骨传导参考阈值水平-一项多中心研究 a)。

Air-conduction and bone-conduction reference threshold levels-A multicenter studya).

机构信息

Arizona State University College of Health Solutions, Tempe, Arizona 85004, USA.

Audiology Incorporated, Arden Hills, Minnesota 55112, USA.

出版信息

J Acoust Soc Am. 2024 Nov 1;156(5):3545-3553. doi: 10.1121/10.0034456.

Abstract

Air-conduction (AC) and bone-conduction (BC) thresholds were measured to evaluate standard reference thresholds and recommend revisions to audiometer standards. AC and BC thresholds were measured from listeners with normal hearing (NH) and sensorineural hearing loss (SNHL) at three sites. NH participants (n = 53) were selected based on age (18-25 years old), normal AC thresholds, tympanometry, otoscopy, and absence of otologic disease. SNHL participants (n = 49) were selected based on AC thresholds, tympanometry, otoscopy, and absence of otologic disease. AC thresholds obtained from NH listeners averaged 3.7 dB hearing level (HL). Air-bone gaps (ABGs) occurred in NH and SNHL listeners above 2000 Hz and in SNHL listeners at 250 Hz. Corrections to standard reference equivalent threshold sound pressure levels are recommended. ABGs in listeners without conductive pathology result from incorrect reference threshold levels for frequencies above 2000 Hz. False ABGs increase with hearing-loss magnitude, probably the result of the effects of ambient and internal noise for low-level BC stimuli. False ABGs place patients at risk for unnecessary medical and surgical intervention. Reference threshold levels should achieve two objectives: (1) AC thresholds from young NH listeners should average 0 dB HL; and (2) ABGs from listeners with normal middle-ear function should average 0 dB.

摘要

空气传导(AC)和骨传导(BC)阈值用于评估标准参考阈值,并为听力计标准的修订提供建议。在三个部位测量了具有正常听力(NH)和感音神经性听力损失(SNHL)的听力者的 AC 和 BC 阈值。NH 参与者(n=53)根据年龄(18-25 岁)、正常 AC 阈值、鼓室图、耳镜检查和无耳科疾病进行选择。SNHL 参与者(n=49)根据 AC 阈值、鼓室图、耳镜检查和无耳科疾病进行选择。NH 听力者的 AC 阈值平均为 3.7 分贝听力水平(HL)。在 2000 Hz 以上的 NH 和 SNHL 听力者以及 250 Hz 的 SNHL 听力者中出现了气骨导差(ABG)。建议对标准参考等效阈声压级进行修正。无传导性病理的听力者的 ABG 是由于高频(2000 Hz 以上)的参考阈值不正确所致。假 ABG 随着听力损失程度的增加而增加,这可能是由于低频 BC 刺激的环境和内部噪声的影响所致。假 ABG 使患者面临不必要的医疗和手术干预的风险。参考阈值应达到两个目标:(1)年轻 NH 听力者的 AC 阈值应平均为 0 dB HL;(2)具有正常中耳功能的听力者的 ABG 应平均为 0 dB。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验