Suppr超能文献

变形链球菌和牙龈卟啉单胞菌对CAD/CAM修复体上釉/抛光表面的黏附作用

Streptococcus-mutans and Porphyromonas-gingivalis adhesion to glazed/polished surfaces of CAD/CAM restorations.

作者信息

Albani Ragad, Habib Syed Rashid, AlQahtani Abdulaziz, AlHelal Abdulaziz A, Alrabiah Mohammed

机构信息

Department of Prosthetic Dental Sciences, College of Dentistry, King Saud University, Riyadh, 11545, Saudi Arabia.

出版信息

Heliyon. 2024 Nov 9;10(22):e40276. doi: 10.1016/j.heliyon.2024.e40276. eCollection 2024 Nov 30.

Abstract

PURPOSE

Dental restorations fabricated using CAD/CAM require modification/adjustment before cementation. Streptococcus mutans and Porphyromonas gingivalis are prevalent bacterial species that may adhere to these materials and can cause caries, gingivitis/periodontitis. The purpose of this in vitro study was to evaluate the bacterial adherence of and to five different kinds of modern CAD/CAM restorative materials with different compositions following chairside finishing/polishing and glazing.

MATERIALS AND METHODS

Specimens (N = 75) from five test materials (n = 15 each) "Tetric-CAD®; IPS-e.max-CAD®; IPS-e.max-ZirCAD®; CELTRA-Duo® and Vita-Enamic®" were prepared in disc shape (10 × 3 mm) using CAD/CAM. The specimens underwent glazing and finishing/polishing using established procedures. The surface roughness was measured in micrometers (μm) using a profilometer. Bacterial adherence to test materials' glazed and finished/polished surfaces was tested using bacterial culture growth over the test materials. Data obtained was tabulated and statistical analysis performed using Kruskal Wallis test, post-hoc Conover test, Mann-Whitney test and Tukey post hoc test.

RESULTS

With the exception of IPS-e.max-ZirCAD®, which showed the contrary, the adherence of was less on glazed surfaces compared to finished/polished surfaces for four test materials: "Tetric-CAD®, IPS-e.max-CAD®, CELTRA-Duo®, and Vita-Enamic®". On the glazed surfaces, the adhesiveness of was not significant (p = 0.099; p = 0.660); however, on the finished/polished surfaces, it was significant (p = 0.002; p = 0.004). With the exception of 'IPS-e.max-ZirCAD®', which showed the reverse behavior, the adhesion of to finished/polished surfaces was greater for each of the four ceramics under investigation "Tetric-CAD®, IPS-e.max-CAD®, CELTRA-Duo®, and Vita-Enamic®".

CONCLUSION

Glazed surfaces for majority of test materials demonstrated decreased adhesion from & , hence prior to final placement of restoration, it is advised to adhere to the minimal glazing criteria. Regardless of the chemical composition of the materials, the surface texture of the tested materials significantly influenced bacterial adhesion.

摘要

目的

使用计算机辅助设计/计算机辅助制造(CAD/CAM)制作的牙科修复体在粘结前需要进行修改/调整。变形链球菌和牙龈卟啉单胞菌是常见的细菌种类,它们可能附着在这些材料上并导致龋齿、牙龈炎/牙周炎。本体外研究的目的是评估在椅旁完成修整/抛光和上釉后,变形链球菌和牙龈卟啉单胞菌对五种不同成分的现代CAD/CAM修复材料的细菌粘附情况。

材料与方法

从五种测试材料(每种n = 15)“Tetric-CAD®;IPS-e.max-CAD®;IPS-e.max-ZirCAD®;CELTRA-Duo®和Vita-Enamic®”制备圆盘状(10×3mm)标本(N = 75),使用CAD/CAM。标本采用既定程序进行上釉和修整/抛光。使用轮廓仪以微米(μm)为单位测量表面粗糙度。通过测试材料上的细菌培养生长来检测细菌对测试材料上釉和修整/抛光表面的粘附情况。将获得的数据制成表格,并使用Kruskal Wallis检验、事后Conover检验、Mann-Whitney检验和Tukey事后检验进行统计分析。

结果

除IPS-e.max-ZirCAD®表现出相反情况外,对于四种测试材料“Tetric-CAD®、IPS-e.max-CAD®、CELTRA-Duo®和Vita-Enamic®”,变形链球菌在釉面的粘附比在修整/抛光表面少。在釉面上,变形链球菌的粘附性不显著(p = 0.099;p = 0.660);然而,在修整/抛光表面,粘附性显著(p = 0.002;p = 0.004)。除IPS-e.max-ZirCAD®表现出相反行为外,在所研究的四种陶瓷“Tetric-CAD®、IPS-e.max-CAD®、CELTRA-Duo®和Vita-Enamic®”中,牙龈卟啉单胞菌对修整/抛光表面的粘附性更大。

结论

大多数测试材料的釉面显示出变形链球菌和牙龈卟啉单胞菌的粘附减少,因此在修复体最终就位前,建议遵循最小上釉标准。无论材料的化学成分如何,测试材料的表面质地显著影响细菌粘附。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c40d/11585799/b41f63eef17f/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验