Wang Yicheng, Schlamminger Stephan
National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD, United States of America.
Metrologia. 2024;61(5). doi: 10.1088/1681-7575/ad7590.
We have built and demonstrated a digital four-arm bridge for the comparison of resistance with capacitance. The digital four-arm bridge mimics the classical quad bridge in the digital domain with three balances: the source balance, the detector balance, as well as the main balance. Due to correlation, the required precision of the source voltages is only of the order of the square root of the ultimate bridge precision. For the comparison of a 100kΩ resistor with a 1 nF capacitor near 1592 Hz, the combined standard uncertainty is 5 × 10).