Abstract

The N-methylmorpholine levels in workroom air in a polyurethane foam factory were determined by two methods in which midget impinger flasks were used for sampling. The analyses were performed by gas chromatography and isotachophoresis. The values obtained by the gas chromatographic method were 19% higher than those of the isotachophoretic method. Determinations of the amine in samples generated in laboratory experiments showed no statistical difference between the two methods. The mean air concentrations of N-methylmorpholine in different work areas of the factory ranged from 7 to 22 mg/m3. Urine was collected from seven workers and analyzed for N-methylmorpholine by gas chromatography. The amine concentrations and the excretion rates increased considerably during the workday.

摘要

在一家聚氨酯泡沫塑料厂中,采用两种使用小型冲击式吸收瓶进行采样的方法测定了工作场所空气中的N-甲基吗啉含量。分析采用气相色谱法和等速电泳法。气相色谱法获得的值比等速电泳法的值高19%。实验室实验中生成的样品中胺的测定结果表明,两种方法之间没有统计学差异。该厂不同工作区域空气中N-甲基吗啉的平均浓度范围为7至22毫克/立方米。收集了7名工人的尿液,并用气相色谱法分析其中的N-甲基吗啉。在工作日期间,胺浓度和排泄率显著增加。