Becciolini Marco, Pivec Christopher, Riegler Georg
Department of Ultrasound, Misericordia di Pistoia, Pistoia, Italy.
Scuola Siumb di Ecografia Muscolo-Scheletrica, Pisa, Italy.
J Ultrason. 2024 Nov 30;24(98):1-5. doi: 10.15557/jou.2024.0027. eCollection 2024 Dec.
The purpose of this study is to present the ultrasound appearance of a previously undescribed-at-imaging variant of the ulnar nerve near the Guyon's canal.
The ultrasound database of one of the authors, who has more than 10 years of experience in peripheral nerve ultrasound, was searched for the phrases "UN variant" or "UN loop." The other two authors, with more than 10 years of experience in nerve imaging, retrospectively reviewed the static sonograms as well as the videoclips stored, to confirm the findings.
Between October 2019 and October 2023, six cases were found in five patients, where ultrasound demonstrated previously undescribed-at-imaging anatomical variations of the distal ulnar nerve on six distal forearms. The variant was symptomatic in three cases in which possible distal compression was clinically suspected. A branch of the ulnar nerve made a loop around the flexor carpi ulnaris, which also presented with a variation of normal anatomy. In symptomatic patients, the diameter of the aberrant branch (retrospectively measured) was significantly enlarged.
High-resolution ultrasound can accurately demonstrate ulnar nerve variants even when only small nerve fascicles are involved, which may be clinically relevant and misinterpreted. Loops of the ulnar nerve are rare, but likely under-recognized. We think that symptoms are generally tolerated by patients if the motor branch of the ulnar nerve is not affected, as in our cases.
本研究旨在呈现腕部Guyon管附近尺神经一种此前影像学未描述过的变异的超声表现。
在一位具有超过10年周围神经超声经验的作者的超声数据库中搜索“尺神经变异”或“尺神经袢”等短语。另外两位具有超过10年神经成像经验的作者回顾性地查看了存储的静态超声图像以及视频片段,以确认研究结果。
在2019年10月至2023年10月期间,在5例患者中发现了6例,超声显示在6条前臂远端的尺神经远端存在此前影像学未描述过的解剖变异。该变异在3例临床上怀疑可能存在远端压迫的病例中出现症状。尺神经的一个分支在尺侧腕屈肌周围形成一个袢,同时尺侧腕屈肌的正常解剖结构也出现了变异。在有症状的患者中,异常分支(回顾性测量)的直径明显增粗。
即使仅涉及小的神经束,高分辨率超声也能准确显示尺神经变异,这些变异可能具有临床相关性且易被误解。尺神经袢很少见,但可能未得到充分认识。我们认为,正如我们的病例所示,如果尺神经的运动分支未受影响,患者通常能够耐受这些症状。