This study evaluated the effect of ProTaper Next (PTN), ProTaper Universal Retreatment (PTR) and hybrid instrumentation (HI) for canal filling removal on the fracture resistance (FR), mode of failure (MoF), and filling removal time.
Ninety-six, mandibular premolars were decoronated and randomly divided into 6 groups ( = 16), as follows: sound (S), untreated canals; prepared teeth (P), canals only prepared to ProTaper Universal finishing instrument (F4); endodontically-treated (ET), prepared and obturated canals using the single-cone technique; and groups PTN, PTR, and HI where filling was removed using PTN, PTR, or HI respectively. FR under vertical loading; MoF and time were assessed. Data were analyzed (Significance level [α] = 0.05).
There was a significant difference in FR among all groups ( < 0.001) (HI < P < PTN < S < ET < PTR). HI showed lower FR than S, ET and PTR, and P showed lower FR than PTR ( < 0.05). For experimental groups, there was a significant difference between every group pair ( < 0.05) No significant difference was found regarding MoF distribution ( > 0.05). HI required the highest filling removal time, while PTR required the least ( < 0.05 between every group pair).
The effect of filling removal on FR may depend on the filling removal technique/system used. PTR could be faster and protect against fracture followed by PTN; HI could adversely affect FR. FR may be associated with filling removal time.
本研究评估了ProTaper Next(PTN)、ProTaper通用再治疗(PTR)和混合器械预备(HI)用于根管充填物去除时对牙齿抗折性(FR)、折断模式(MoF)和充填物去除时间的影响。
96颗下颌前磨牙去除牙冠后随机分为6组(每组n = 16),如下:完好组(S),未治疗的根管;预备组(P),根管仅预备至ProTaper通用修整器械(F4);根管治疗组(ET),采用单尖法预备并充填根管;以及PTN组、PTR组和HI组,分别使用PTN、PTR或HI去除充填物。评估垂直加载下的FR、MoF和时间。对数据进行分析(显著性水平[α]=0.05)。
所有组之间的FR存在显著差异(P<0.001)(HI<P<PTN<S<ET<PTR)。HI组的FR低于S组、ET组和PTR组,P组的FR低于PTR组(P<0.05)。对于实验组,每组之间均存在显著差异(P<0.05)。在MoF分布方面未发现显著差异(P>0.05)。HI组所需的充填物去除时间最长,而PTR组所需时间最短(每组之间P<0.05)。
充填物去除对FR的影响可能取决于所使用的充填物去除技术/系统。PTR可能更快且能防止牙齿折断,其次是PTN;HI可能会对FR产生不利影响。FR可能与充填物去除时间有关。