Suppr超能文献

使用两种光声成像系统获得的淋巴管图像质量比较。

Comparison of the Quality of Lymphatic Vessel Images Obtained Using Two Photoacoustic Imaging Systems.

作者信息

Suzuki Yushi, Kajita Hiroki, Otaki Marika, Watanabe Shiho, Okabe Keisuke, Sakuma Hisashi, Takatsume Yoshifumi, Asano Yuta, Soga Shigeyoshi, Imanishi Nobuaki, Sato Imari, Jinzaki Masahiro, Kishi Kazuo

机构信息

From the Department of Plastic and Reconstructive Surgery, Keio University School of Medicine, Tokyo, Japan.

Tokyo Dental Colledge Ichikawa General Hospital, Chiba, Japan.

出版信息

Plast Reconstr Surg Glob Open. 2024 Dec 6;12(12):e6388. doi: 10.1097/GOX.0000000000006388. eCollection 2024 Dec.

Abstract

Photoacoustic imaging (PAI) can evaluate lymphatic vessels with a high resolution (0.2 mm) compared with other methods. LUB0, a new PAI device that is smaller than the PAI-05 used since 2020 (both from Luxonus, Inc.), has been introduced. We aimed to determine the imaging capability of LUB0 by comparing it with that of PAI-05. Two healthy individuals and 4 patients with lymphedema underwent PAI using PAI-05 and LUB0. Each participant was subcutaneously injected with indocyanine green to visualize the lymphatic vessels. PAI was performed after confirming that the lymphatic flow had moved to the central part of the body using a near-infrared camera. Four physicians selected a device with superior image clarity based on a 5-point scale. LUB0 produced sharper images of lymphatic vessels and veins than PAI-05. The physicians scored 3.0 ± 1.2 with PAI-05 and 3.9 ± 0.9 with LUB0 ( < 0.05), implying that LUB0 provided significantly clearer images. Additionally, the dermal backflow image obtained using LUB0 from a patient with lymphedema depicted the precollector lymphatic vessels more clearly. LUB0 occupies approximately one-seventh of the footprint of PAI-05 and requires a shorter imaging time (5 minutes) than PAI-05 (10 minutes). The PAI model LUB0 improved the visualization of lymphatic vessels and veins, allowing better detection and evaluation of lymphatic vessels.

摘要

与其他方法相比,光声成像(PAI)能够以高分辨率(0.2毫米)评估淋巴管。已推出一种新型PAI设备LUB0,它比自2020年以来使用的PAI-05(均来自Luxonus公司)更小。我们旨在通过将LUB0与PAI-05进行比较来确定其成像能力。两名健康个体和4名淋巴水肿患者使用PAI-05和LUB0进行了PAI检查。给每位参与者皮下注射吲哚菁绿以可视化淋巴管。在使用近红外相机确认淋巴液流向身体中央部分后进行PAI检查。四名医生根据5分制选择图像清晰度更高的设备。与PAI-05相比,LUB0生成的淋巴管和静脉图像更清晰。医生对PAI-05的评分是3.0±1.2,对LUB0的评分是3.9±0.9(<0.05),这意味着LUB0提供的图像明显更清晰。此外,使用LUB0从一名淋巴水肿患者获得的真皮逆流图像更清晰地描绘了收集前淋巴管。LUB0占地面积约为PAI-05的七分之一,成像时间(5分钟)比PAI-05(10分钟)短。PAI模型LUB0改善了淋巴管和静脉的可视化,有助于更好地检测和评估淋巴管。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/654e/11623897/466a0c35fadb/gox-12-e6388-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验