Suppr超能文献

耳罩式耳机中辛酰异噻唑啉酮引起的严重过敏性接触性皮炎:病例系列

Severe Allergic Contact Dermatitis From Octylisothiazolinone in Over-Ear Headphones: A Case Series.

作者信息

Menanteau Marion, Fenech Goël, Adam Benjamin, Langlois Eddy, Marcant Pierre, Pelletier Eric, Staumont-Sallé Delphine, Bensefa-Colas Lynda, Crepy Marie-Noëlle

机构信息

Department of Occupational and Environmental Diseases, Hotel-Dieu Hospital, AP-HP Centre - Université Paris Cité, AP-HP, Paris, France.

Université Paris Cité, CRESS-INSERM UMR-1153, HERA Team, Paris, France.

出版信息

Contact Dermatitis. 2025 Apr;92(4):291-298. doi: 10.1111/cod.14733. Epub 2024 Dec 10.

Abstract

BACKGROUND

Octylisothiazolinone (OIT; CAS 26530-20-1) is used as a biocide in leather products.

OBJECTIVES

To report several cases of allergic contact dermatitis (ACD) from the use of headphones containing OIT, and to highlight the strong allergic potential of this preservative.

PATIENTS AND METHODS

Four patients with ACD from headphones were patched tested using the European baseline, cosmetic, rubber, plastics/glues and acrylates series. Patients were also tested to different parts of their own headphones ('as is'). Chemical analyses of the headphones was additionally performed with Ultra Performance Liquid Chromatography-tandem mass spectrometry (UPLC-MS/MS).

RESULTS

All patients had developed localised ACD to the contact sites of the headphones, except for one patient who developed 'angioedema-like' dermatitis. All patients were shown to have been primarily sensitised to OIT. UPLC-MS/MS analysis confirmed OIT in the leather ear pads of the headphones.

CONCLUSIONS

OIT is a relevant and strong sensitizer in leather, and may cause severe ACD. Safer use concentrations (limits) of OIT, as well as product labelling in the leather industry, may be required to ensure a better protection of consumers.

摘要

背景

辛基异噻唑啉酮(OIT;化学物质登记号26530-20-1)在皮革制品中用作杀生剂。

目的

报告几例因使用含OIT的耳机而发生过敏性接触性皮炎(ACD)的病例,并强调这种防腐剂具有很强的过敏潜力。

患者与方法

对4例因耳机导致ACD的患者使用欧洲基线、化妆品、橡胶、塑料/胶水和丙烯酸酯系列进行斑贴试验。还对患者自己耳机的不同部位进行了“原样”测试。另外使用超高效液相色谱-串联质谱法(UPLC-MS/MS)对耳机进行化学分析。

结果

除1例出现“血管性水肿样”皮炎的患者外,所有患者均在耳机接触部位出现局限性ACD。所有患者均显示对OIT原发性致敏。UPLC-MS/MS分析证实耳机皮革耳垫中存在OIT。

结论

OIT在皮革中是一种相关且强效的致敏剂,可能导致严重的ACD。可能需要OIT更安全的使用浓度(限值)以及皮革行业的产品标签,以确保更好地保护消费者。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1df7/11880882/fe037232f93e/COD-92-291-g003.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验